![PulseTec ULTIMA 400 DUO Instruction Manual Download Page 22](http://html1.mh-extra.com/html/pulsetec/ultima-400-duo/ultima-400-duo_instruction-manual_1625698022.webp)
22
[ TIME: 00:04:04 ]
9.6V 00640mAh
NiMH RE-PEAK
2
NiMH 1.3A 10.42V
RPC 004:04 00686
START/ENTER
When discharging is complete, the screen will read
“END: CUTOFF-VOL” and the charger will emit a ringing sound.
The charger will display the elapsed time, end voltage and the dis-
charged capacity in mAh.
You can press the STOP button at any time during the discharging
process to stop the discharge process.
After selecting the correct battery type, use the INC or DEC button
to select the “RE-PEAK” mode. Press the START button and the
Re-peak cycle number 1 begins to flash on the screen. Use the INC
or DEC button to scroll through the cycle count and set a number
between 1 and 3.
Press and hold the START button for 3 seconds to start the re-peak
process.
Once the Re-Peak process has begun, the charger will display the
following real-time information: battery type, charging current, bat-
tery voltage, elapsed time and charged capacity. Once the Re-Peak
process has completed, the screen will read “END: RE-PEAK” and
the charger will emit a ringing sound. The charger will display the
charge/discharge capacity for each cycle. Using the + and - buttons,
you can scroll through the history data of each cycle.
NiMH/NiCd Re-Peak Mode :
Applicable to NiMH and NiCD batteries only, in re-peak mode the charger can peak-
charge the battery once, twice, or three times in a row automatically. This process is good
for confirming that the battery is fully charged and for verifying how well the battery can
accept a fast charge. A five-minute cool-down delay occurs after each re-peak charge.
IN RE-PEAK MODE, THE ULTIMA 400 DUO USES THE CHARGE AMPERAGE AND
VOLTAGE SETTINGS ENTERED IN CHARGE MODE.
Battery Program (NiMH/NiCD)