        3.2 Optical indication of the switch operation (see Table 8). 
 

Table 8. Indication of the switch operation 

OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY 

 

GREEN LED LIGHT (Power) 
Indication of the switch's 
power supply 

 

 

OFF

 

– no power supply of the switch 

ON

 

– power supply on, normal operation 

 

OPTICAL INDICATION AT THE POE PORTS (1

÷4) 

 

GREEN LED LIGHT (PoE) 
Indication of the PoE power 
supply at the RJ45 ports 
 

 

 

OFF

- no power supply at the RJ45 port (the device is not connected or not compliant with 

the IEEE802.3af/at standard) 

ON

 

– supply at the RJ45 port 

Blinking

 

– short-circuit or output overload 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices, 10 Mb/s or 100 Mb/s 
and data transmission 

 

 

OFF

- no connection 

ON 

- the device is connected; 10 Mb/s or 100 Mb/s 

Blinking

 

– data transmission 

 

OPTICAL INDICATION AT THE UP LINK PORTS 

 

GREEN LED LIGHT 

 

Port on the left side: 

No lit

 - no voltage 

Lit 

– switch operates properly

 

Port on the right side: 

No

 

lit 

– switch operates in normal mode 

Lit

– Long Range mode active

 

YELLOW LED LIGHT (LINK) 
The connection status of 
LAN devices, 10 Mb/s or  
100 Mb/s and data 
transmission 

 

 

OFF

- no data transmission 

ON 

- the device is connected: 10 Mb/s or 100 Mb/s 

Blinking

 

– data transmission 

 
 

 

 

Installation example of the S64-CRB with batteries and the recorder  

(DVR and accumulators are not included) 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for S64-CRB

Page 1: ...date two 17 Ah 12 V batteries and offers the possibility of recorder installation The enclosure construction is compliant with the requirements of the General Data Protection Regulation GDPR the possi...

Page 2: ...ectricity consumption for own needs and the energy efficiency of the power intake track were taken into account The exact description of how to perform the calculations can be found at Approximate bac...

Page 3: ...C DC52115 converter 4 DC DC50SD converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Space for batteries 2 x 17 Ah 12 V connect the batteries in series 8 Recorder space...

Page 4: ...2 3x CSMA CD TCP IP Bandwidth 1 6 Gbps Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 30 W per port is the maximum val...

Page 5: ...PSU between input circuit and protection circuit between output circuit and protection circuit 3000 V AC min 1500 V AC min 500 V AC min Insulation resistance between input circuit and output or prote...

Page 6: ...tart 2 3 Installation procedure Before installation cut off the voltage in the 230 V power supply circuit To switch power off use an external switch in which the distance between the contacts of all p...

Page 7: ...3 1 LED indication of operating status The PSU is equipped with two diodes on the front panel RED LED on the PSU is supplied with 230 V off no 230 V supply GREEN LED on DC voltage in the AUX output o...

Page 8: ...g short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10 Mb s or 100 Mb s and data transmission OFF no connection ON the device is connected 10 Mb s or 100 Mb s...

Page 9: ...rk The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replacem...

Reviews: