background image

 

 

1.3  Description of components and connectors. 

 

 

 

Fig. 2. The enclosure view. 

Table 1. (See Fig. 2) 

Component No. 

(Fig. 2) 

Description 

[1] 

Switch PoE  

[2] 

Switch mode buffer power supply unit 

[3] 

DC/DC52115 converter 

[4] 

DC/DC50SD converter 

[5] 

Output filter 

[6] 

Tamper 

– micro switch (terminals) of tamper protection (NC) 

[7] 

Space for batteries (2 x 17 Ah/12 V

– connect the batteries in series) 

[8] 

Recorder space 380x320x65 (WxHxD)

 

[9] 

Power supply connector of  the PSU 

– L, N  

Protective connector 

 

[10] 

BAT +, BAT -  battery  BAT red,  - BAT black 

[11] 

DVR power cord terminated with the DC 2,1/5,5 plug 

 

Summary of Contents for S64-CRB

Page 1: ...date two 17 Ah 12 V batteries and offers the possibility of recorder installation The enclosure construction is compliant with the requirements of the General Data Protection Regulation GDPR the possi...

Page 2: ...ectricity consumption for own needs and the energy efficiency of the power intake track were taken into account The exact description of how to perform the calculations can be found at Approximate bac...

Page 3: ...C DC52115 converter 4 DC DC50SD converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Space for batteries 2 x 17 Ah 12 V connect the batteries in series 8 Recorder space...

Page 4: ...2 3x CSMA CD TCP IP Bandwidth 1 6 Gbps Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 30 W per port is the maximum val...

Page 5: ...PSU between input circuit and protection circuit between output circuit and protection circuit 3000 V AC min 1500 V AC min 500 V AC min Insulation resistance between input circuit and output or prote...

Page 6: ...tart 2 3 Installation procedure Before installation cut off the voltage in the 230 V power supply circuit To switch power off use an external switch in which the distance between the contacts of all p...

Page 7: ...3 1 LED indication of operating status The PSU is equipped with two diodes on the front panel RED LED on the PSU is supplied with 230 V off no 230 V supply GREEN LED on DC voltage in the AUX output o...

Page 8: ...g short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10 Mb s or 100 Mb s and data transmission OFF no connection ON the device is connected 10 Mb s or 100 Mb s...

Page 9: ...rk The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replacem...

Reviews: