Short-circuit protection SCP and overload protection OLP 

105% ÷ 150% PSU power, manual restart (the fault requires 

disconnection of the DC output circuit) 

PSU current consumption 

150 mA/27,6 V 

Battery charge current 

0,5 A max. / 2x17 Ah (+/-5%) 

Approximate backup time 

6h  

Battery circuit protection SCP and reverse  
polarity connection 

melting fuse 

Deep discharge battery protection UVP  

U<19 

V (± 5%) – disconnect of connection battery 

Sabotage protection: 
- TAMPER output indicating enclosure opening 

 

- microswitch, NC contacts (enclosure closed), 

0,5 A@50 V DC (max.) 

 

 

 

Table 5. Mechanical parameters 

Dimensions 

W=397, H=350, D+D

1

=92+8 [+/- 2mm] 

W

1

=402, H

1

=355 [+/- 2mm] 

The dimensions of the battery 
compartment 

370 x 180 x 80mm (WxHxD) max   

Gross/Net weight 

4,8 / 5,1 kg 

Enclosure 

Steel plate, DC01 1,0mm color white RAL 9003 

Closing 

Cheese head screw x 2 (at the front), (lock assembly possible) 

Connectors 

Power supply of the cameras:  RJ45 socket  
Power supply of the DVR: DC plug 2,1/5,5 
Outputs: 

Φ 0,63-2,50 (AWG 22-10)  

Battery output BAT: 6,3F-2,5  
TAMPER output: wires  

Notes 

The enclosure does not touch the assembly surface so that cables can be led. 

 
Table 6. Operation safety 

Protection class PN-EN 609501:2007  

I (first) 

Protection grade PN-EN 60529: 2002 (U)  

IP20 

Electrical strength of insulation: 
- between input and output circuits of the PSU  
- between input circuit and protection circuit  
- between output circuit and protection circuit  

 

3000 V AC min. 
1500 V AC min. 

   500 V AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 

100 

MΩ, 500 V DC 

Declarations 

CE 

 

Table 7. Operating parameters

 

Operating temperature 

-

10ºC...+40ºC 

Storage temperature 

-

20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insulation 

unacceptable 

Vibrations and impulse waves during transport 

According to PN-83/T-42106 

 
 
 
 
 
 
 

Summary of Contents for S64-BR

Page 1: ...me 6h LED indication Metal enclosure color white RAL 9003 which can accommodate two 17Ah 12V batteries Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the productio...

Page 2: ...ption of how to perform the calculations can be found at Approximate backup time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 4 p...

Page 3: ...y unit 3 DC DC50SD converter 4 DC DC52115 converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Space for batteries 2 x 17 Ah 12 V connect the batteries in series 8 Power...

Page 4: ...802 3af at 1 4 ports 52 V DC 30 W at each port Used pairs 1 2 3 6 Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Bandwidth 1 6Gbps Transmission method Store and Forward Optical indication...

Page 5: ...assembly possible Connectors Power supply of the cameras RJ45 socket Power supply of the DVR DC plug 2 1 5 5 Outputs 0 63 2 50 AWG 22 10 Battery output BAT 6 3F 2 5 TAMPER output wires Notes The enclo...

Page 6: ...system shall follow valid standards and regulations 2 2 Installation procedure Before installation cut off the voltage in the 230 V power supply circuit To switch power off use an external switch in w...

Page 7: ...3 1 LED indication of operating status The PSU is equipped with two diodes on the front panel RED LED on the PSU is supplied with 230 V off no 230 V supply GREEN LED on DC voltage in the AUX output o...

Page 8: ...the IEEE802 3af at standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10Mb s or 100Mb s and data transmission OFF...

Page 9: ...k The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replaceme...

Reviews: