5
Short-circuit protection SCP and overload protection OLP
105% ÷ 150% PSU power, manual restart (the fault requires
disconnection of the DC output circuit)
PSU current consumption
150 mA/27,6 V
Battery charge current
0,5 A max. / 2x17 Ah (+/-5%)
Approximate backup time
6h
Battery circuit protection SCP and reverse
polarity connection
melting fuse
Deep discharge battery protection UVP
U<19
V (± 5%) – disconnect of connection battery
Sabotage protection:
- TAMPER output indicating enclosure opening
- microswitch, NC contacts (enclosure closed),
0,5 A@50 V DC (max.)
Table 5. Mechanical parameters
Dimensions
W=397, H=350, D+D
1
=92+8 [+/- 2mm]
W
1
=402, H
1
=355 [+/- 2mm]
The dimensions of the battery
compartment
370 x 180 x 80mm (WxHxD) max
Gross/Net weight
4,8 / 5,1 kg
Enclosure
Steel plate, DC01 1,0mm color white RAL 9003
Closing
Cheese head screw x 2 (at the front), (lock assembly possible)
Connectors
Power supply of the cameras: RJ45 socket
Power supply of the DVR: DC plug 2,1/5,5
Outputs:
Φ 0,63-2,50 (AWG 22-10)
Battery output BAT: 6,3F-2,5
TAMPER output: wires
Notes
The enclosure does not touch the assembly surface so that cables can be led.
Table 6. Operation safety
Protection class PN-EN 609501:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input and output circuits of the PSU
- between input circuit and protection circuit
- between output circuit and protection circuit
3000 V AC min.
1500 V AC min.
500 V AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100
MΩ, 500 V DC
Declarations
CE
Table 7. Operating parameters
Operating temperature
-
10ºC...+40ºC
Storage temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insulation
unacceptable
Vibrations and impulse waves during transport
According to PN-83/T-42106