background image

 

  

 

Connection schemes

 

 

 

 

 

        

 

 
3. Indication of the device operation. 
 

3.1 LED indication of operating status. 

The PSU is equipped with two diodes on the front panel: 

 

 

 

RED LED: 

 

on – the PSU is supplied with 230 V   

 

off – no 230 V supply 

 

GREEN LED: 

 

on – DC voltage in the AUX output of the PSU 

 

off – no DC voltage in the AUX output of the PSU 

 

 

 
 
 
 
 
 

Summary of Contents for S64-BR

Page 1: ...me 6h LED indication Metal enclosure color white RAL 9003 which can accommodate two 17Ah 12V batteries Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the productio...

Page 2: ...ption of how to perform the calculations can be found at Approximate backup time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 4 p...

Page 3: ...y unit 3 DC DC50SD converter 4 DC DC52115 converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Space for batteries 2 x 17 Ah 12 V connect the batteries in series 8 Power...

Page 4: ...802 3af at 1 4 ports 52 V DC 30 W at each port Used pairs 1 2 3 6 Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Bandwidth 1 6Gbps Transmission method Store and Forward Optical indication...

Page 5: ...assembly possible Connectors Power supply of the cameras RJ45 socket Power supply of the DVR DC plug 2 1 5 5 Outputs 0 63 2 50 AWG 22 10 Battery output BAT 6 3F 2 5 TAMPER output wires Notes The enclo...

Page 6: ...system shall follow valid standards and regulations 2 2 Installation procedure Before installation cut off the voltage in the 230 V power supply circuit To switch power off use an external switch in w...

Page 7: ...3 1 LED indication of operating status The PSU is equipped with two diodes on the front panel RED LED on the PSU is supplied with 230 V off no 230 V supply GREEN LED on DC voltage in the AUX output o...

Page 8: ...the IEEE802 3af at standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10Mb s or 100Mb s and data transmission OFF...

Page 9: ...k The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replaceme...

Reviews: