background image

www.pulsar.pl 

 

 

 

 

PSUPS10A12 

 

 

 

 

 
 

1.4. Specifications: 

- electrical specifications (tab.3) 
- mechanical specifications (tab.4) 
- operation safety (tab.5) 
- operating specifications (tab.6)

 

 
Table 3. Electrical specifications. 

PSU type 

A (EPS - External Power Source) 

Mains supply 

230V AC (-15%/+10%) 

Current consumption 

1,1A @230V AC 

PSU’s power 

152W  

Efficiency 

79% 

Output voltage 

11

V ÷ 12V DC – buffer operation 

10

V ÷ 12V DC – battery-assisted operation 

Output current 

9A (8x0,5A +1x5A) + 2A battery charging 

Output voltage adjustment range 

12

÷14,5V DC 

Ripple voltage 

20mV p-p max. 

PSU current consumption  

50mA max 

Battery charging current 

1A / 2A / 3A / 5A - jumper selectable 

Short-circuit protection SCP  

LB8 STRIP:  8x F 0,5A glass fuse, 
LB1 STRIP: 1xF5A 
PSU module: 
Electronic - current limitation and/or activation of the F

BAT

 

melting fuse in the battery circuit (failure requires fuse 
replacement) 
Automatic return 

Overload protection OLP 

110% ÷ 150% of the PSU power – electronic. 
Disconnection of the PSU outputs 

– automatic return after DC 

output circuit disconnection 

Battery circuit protection SCP and reverse 
polarity connection 

T10A 

– current limiting, F

BAT 

fuse (failure requires fuse-

element replacement) 

Surge protection 

varistors 

Over voltage protection OVP  

U>16V (automatic return)  

Deep discharge protection UVP 

U<10V (± 0,5V) – disconnection of battery terminal 

Sabotage protection: 
- TAMPER output indicating enclosure opening 

 
- micro-switches x2, NC contacts (enclosure closed and fixed 
to the surface), 0,5A@50V DC (max.) 

Optical indication: front panel of the PSU 
- AC OK.; LED indicating  the AC power status 
 
- DC OK.; LED indicating  the DC supply at the 
PSU output  
 
- BAT OK.; LED indicating  the battery voltage 

 
- red, normal operation: permanently illuminated, 
failure: off 
- green, permanently illuminated, failure: off 
 
- green, permanently illuminated, 
failure: off 

Technical outputs: 
- EPS; output indicating AC power failure 
 
 
 
 
- PSU; output indicating no DC power/PSU 
failure  
 
 
- LoB output indicating low battery voltage 

 
-  OC type: 50mA max.  
 

Normal operation: L state (0V), 

 

failure: hi-Z state, 

- delay time 10s/60s (+/-20%) 

– jumper selectable 

T

AC

  

 
- OC type: 50mA max.  
 

Normal operation: L state (0V), 

 

failure: hi-Z state,  

 
- OC type, 50mA max.  
 

Normal operation (U

BAT

 >11,5V): L state (0V), 

 

failure (U

BAT

 <11,5V):  hi-Z state 

F

BAT 

fuse

 

F

MAIN 

fuse  

Recorder’s module fuse (fig.3 [7])  
Cameras module fuse (fig.3 [9]) 

T 10A / 250V 
T 6,3A / 250V  
F 5A/250V 
F 0,5A/250V 

             

 
 
 
 
 
 

Summary of Contents for PSUPS10A12

Page 1: ...PSUPS10A12 v 1 3 PSUPS 13 8V 12V 10A 40Ah Buffer power supply for 8 cameras and recorder EN Edition 6 from 25 05 2015 Supercedes the edition 5 from 06 08 2014...

Page 2: ...utputs of the OC type to relay adjustable times of 230V AC failure indication protections SCP short circuit protection OLP overload protection OVP over voltage protection OHP overheat protection surge...

Page 3: ...rcuit Board see Fig 2 Element no Description 1 PBAT pin configuration of the battery protection system UVP PBAT discharged battery disconnection system OFF PBAT discharged battery disconnection system...

Page 4: ...ig 3 Element no Fig 3 Description outputs of the PSU 1 Insolation transformer 2 PSU board tab 1 3 TAMPER micro switch contacts of tamper resistance NC 4 FMAIN fuse in the supply circuit 230V AC T6 3A...

Page 5: ...www pulsar pl PSUPS10A12 5 Fig 3 The view of the PSU...

Page 6: ...olarity connection T10A current limiting FBAT fuse failure requires fuse element replacement Surge protection varistors Over voltage protection OVP U 16V automatic return Deep discharge protection UVP...

Page 7: ...60 C Relative humidity 20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insolation unacceptable Vibrations and impulse waves duri...

Page 8: ...to the technical outputs EPS technical output indicating AC power failure PSU technical output indicating PSU failure LoB technical output indicating low battery voltage Optional installation of the M...

Page 9: ...fig 2 red diode indicates activation of the over voltage protection OVP Under normal status the diode is off If the converter s voltage exceeds 16V the diode is permanently illuminated 3 2 Technical o...

Page 10: ...ration of the voltage at the BAT output requires the replacement of the fuse 4 2 Overload or short circuit of the recorder s module or CCTV camera module The modules of the recorder and CCTV cameras a...

Page 11: ...ir period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms b...

Page 12: ...www pulsar pl PSUPS10A12 12 Pulsar Siedlec 150 32 744 apczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zasilacze pl...

Reviews: