background image

www.pulsar.pl                                                             PSDCB09129C            

 

 

5

 

Voltage adjustment range 

13,5 

– 14 V 

Ripple 

100 mV p-p max. 

Battery charge current 

1 / 4A (± 5%) 

Space for battery 

17Ah/12V (SLA) 

Approximate backup time 

2h 30min 

Short-circuit protection SCP 

LB9  STRIP 
9x glass fuse  

Overload protection OLP 

105 

÷ 150% of power supply, automatic recovery 

Battery circuit protection SCP and reverse 
polarity connection 

glass fuse T10A/250V   

Surge protection 

varistors 

Overvoltage protection OVP 

>19V (automatic recovery) 

Excessive discharge protection UVP 

U<9,5V (

± 5%) – disconnect of connection battery 

Tampering protection system: 
- TAMPER 

– indicating unwanted opening of the 

PSU’s enclosure 

- microswitch, NC contacts (enclosure closed), 
0,5A@50 V DC (max.) 

LED indication:  
- AC diode indicating AC power status 
- AUX diode indicating DC power status at PSU 
output 

- red, normal status: permanently illuminated, failure: off 
- green, normal status: permanently illuminated,  
  failure: off 

F1÷F9 

F 1A/250V 

 

 

        
     Mechanical parameters (tab. 4) 

Dimensions 

W=300, H=300, D+D

1

=105+8 [+/- 2mm] 

W

1

=305, H

1

=305 [+/- 2mm] 

Fitting battery 

185x170x90mm (WxHxD) max 

Fixation 

see figure 3 

Net/gross weight 

2.7 / 2.85 [kg] 

Enclosure 

Steel plate, DC01  0,7mm colour: RAL 9003 

Closing 

Cheese head screw x 2 (at the front), lock assembly possible 

Connectors 

Power supply: 

Φ0,63-2,50 (AWG 22-10) 

Outputs

Ф0,41÷1,63 (AWG 26-14),  

Battery output BAT: 6,3F-2,5  
TAMPER output: wires  

Notes 

The enclosure does not adjoin the assembly surface so that cables can be led. 

     
      Operation safety (tab. 5) 

Protection class EN 62368-1 

I (first) 

Protection grade EN 60529 

IP20 

Electrical strength of insulation: 
- between input and output circuits of the PSU  
- between input circuit and protection circuit  
- between output circuit and protection circuit 

 

 
2500 V AC min. 
1500 V AC min. 
  500 V AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500 V DC  

   
       Operating parameters (tab. 6) 

Operating temperature 

-

10ºC...+40ºC  

Storage temperature 

-

20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Summary of Contents for PSDCB09129C

Page 1: ...PSDCB09129C v 1 1 PSDCB 13 8V 9A 9x1A 17Ah Buffer power supply for up to 9 HD cameras EN Edition 8 from 23 03 2022 Supercedes edition 7 from 15 11 2017 GREEN POWER CCTV...

Page 2: ...onnection LED indication protections SCP short circuit protection OVP overvoltage protection overvoltage protection against sabotage overload protection OLP warranty 2 years from production date An ex...

Page 3: ...needs and the energy efficiency of the power intake track were taken into account The exact description of how to perform the calculations can be found at Approximate backup time assumptions for calc...

Page 4: ...ction connector 5 Cable ellipse opening 6 TAMPER contact of sabotage protection NC 7 BAT GND battery outputs BAT red GND black 8 Fuse module LB9 Fig 3 The view of the PSU 1 4 Specifications electrical...

Page 5: ...lure off F1 F9 F 1A 250V Mechanical parameters tab 4 Dimensions W 300 H 300 D D1 105 8 2mm W1 305 H1 305 2mm Fitting battery 185x170x90mm WxHxD max Fixation see figure 3 Net gross weight 2 7 2 85 kg E...

Page 6: ...appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230 V power supply circu...

Page 7: ...ls will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require pe...

Reviews: