background image

www.pulsar.pl                                                             PSDCB09129C            

 

 

4

 

 

Table 2. Description of PSU components and connectors (tab. 2)

 

Element no. 

 [Fig. 3] 

Description 

[1] 

P1 potentiometer, 

output voltage adjustment 

[2] 

PSU module 

[3] 

Selection jumper for charging current: 

                    

  Ibat =1A             

  Ibat =4A 

Description: 

 jumper installed, 

  jumper removed 

Factory settings: Ibat =1A (jumper installed) 

[4] 

L-N  

power supply connector,  

 PE protection connector 

[5] 

Cable ellipse opening 

[6] 

TAMPER,  

contact of sabotage protection 

(NC)

 

[7] 

BAT+/GND: battery outputs 

+ BAT=

 

red, GND=

 

black

 

[8] 

Fuse module LB9 

 

Fig.3. The view of the PSU. 

1.4 Specifications:  

- electrical parameters (tab. 3) 
- mechanical parameters (tab. 4) 
- operation safety (tab. 5) 
- operating parameters (tab. 6) 

 
      

Electrical parameters (tab. 3) 

Mains supply 

~200 - 240 V 

Current up to 

1,3 A  

Supply power 

138 W  

Efficiency 

87% 

Output voltage 

11 - 13,8 V DC 

– buffer operation 

9,5 - 13,8 V DC 

– battery-assisted operation 

Output current 

9x1 A + 1 A battery charge  
9x0,66 A + 4 A battery charge  

Summary of Contents for PSDCB09129C

Page 1: ...PSDCB09129C v 1 1 PSDCB 13 8V 9A 9x1A 17Ah Buffer power supply for up to 9 HD cameras EN Edition 8 from 23 03 2022 Supercedes edition 7 from 15 11 2017 GREEN POWER CCTV...

Page 2: ...onnection LED indication protections SCP short circuit protection OVP overvoltage protection overvoltage protection against sabotage overload protection OLP warranty 2 years from production date An ex...

Page 3: ...needs and the energy efficiency of the power intake track were taken into account The exact description of how to perform the calculations can be found at Approximate backup time assumptions for calc...

Page 4: ...ction connector 5 Cable ellipse opening 6 TAMPER contact of sabotage protection NC 7 BAT GND battery outputs BAT red GND black 8 Fuse module LB9 Fig 3 The view of the PSU 1 4 Specifications electrical...

Page 5: ...lure off F1 F9 F 1A 250V Mechanical parameters tab 4 Dimensions W 300 H 300 D D1 105 8 2mm W1 305 H1 305 2mm Fitting battery 185x170x90mm WxHxD max Fixation see figure 3 Net gross weight 2 7 2 85 kg E...

Page 6: ...appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230 V power supply circu...

Page 7: ...ls will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require pe...