background image

www.pulsar.pl 

 

 

 

 

PSDC04122T 

 

 

 

 

 
 

 
 
1.4. Specifications: 
- electrical specifications (tab.3) 
- mechanical specifications (tab.4) 
- operation safety (tab.5) 
- operating specifications (tab.6) 

 
Electrical specifications (tab. 3). 

Supply voltage 

176 ÷ 264V AC  

Current consumption 

0,18A @230VAC max. 

PSU power 

25Wmax. 

Efficiency 

74% 

Output voltage 

12V DC 

Output current 

4x 0,5A (

Σ

 I = 2A) max. @12V 

Output voltage adjustment range 

12V÷ 15VDC  

Ripple voltage 

100mV p-p max. 

Short-circuit protection SCP  

LB4  STRIP 
4x F 0,5A fuse  
PSU MODULE 
105% ÷ 150% of PSU power, electronic current limiting 

Overload protection OLP 

105% ÷ 150% of PSU power, electronic current limiting 

Surge protection 

varistors 

Overvoltage protection OVP

 

>16V  (automatic recovery) 

F1÷ F4 fuses  

F 0,5A/250V  

Mechanical specifications (tab. 4). 

Enclosure dimensions 

230 x 176 x 59

 

(235 x 181 x 51+8)  (WxHxD) [mm] (+/- 2) 

Fixing 

201 x 146 x 4 szt. 

Φ

 6  (WxH) 

Net/gross weight 

1,04/1,19 kg 

Enclosure 

Steel plate, DC01 0,7mm colour: RAL 9003 

Closing 

Cheese-head screw: at the front 

Connectors 

Power supply: 230V AC: 

Φ

0,63-2,05 (AWG 22-12) 

AUX outputs: 

Φ

0,51- 2,05 (AWG 24-12) 

LB4: 

Φ

0,51- 2,05 (AWG 24-12) 

Notes 

The enclosure does not adjoin the assembly surface so that cables can be led. 
Convectional cooling. 

Operation safety (tab.5). 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between input (network) circuit and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000V/AC min. 
1500V/AC min. 
500V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 M

, 500V/DC  

Operating specifications (tab.6). 

Operating temperature 

-10ºC...+50ºC  

Storage temperature 

-25ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and impulse waves during transport 

PN-83/T-42106 

 
 
 
 
 
 
 

Summary of Contents for PSDC04122T

Page 1: ...PSDC04122T v 1 0 PSDC 12V 2A 4x0 5A TOPIC Switched mode power supply for CCTV EN Edition 2 from 25 02 2013 Supersedes the 1 from 08 01 2013 edition ...

Page 2: ...ation procedure 3 Operating status indication 3 1 LED indication 4 Operation and use 4 1 Overload or short circuit at the PSU output 4 2Maintenance 1 Technical description 1 1 General description The stabilized PSU PSDC04122T is intended for supplying CCTV devices requiring stabilised voltage of 12V DC The output voltage adjustment range is adjusted via a potentiometer within the range of 12 0V 15...

Page 3: ... of the LB4 strip 4 AUX1 AUX4 outputs COM shared terminal Fig 2 The view of the PSU s pcb Table 2 Elements of the PSU see fig 3 Element no Description 1 L N 230 V AC power connectors PE protection connector 2 PSU module 3 VADJ potentiometer output voltage adjustment within the range of 12 0V 15 0V DC 4 LED indication of DC power status main module of the PSU 5 LB4 fuse strip with power outputs and...

Page 4: ... Enclosure Steel plate DC01 0 7mm colour RAL 9003 Closing Cheese head screw at the front Connectors Power supply 230V AC Φ0 63 2 05 AWG 22 12 AUX outputs Φ0 51 2 05 AWG 24 12 LB4 Φ0 51 2 05 AWG 24 12 Notes The enclosure does not adjoin the assembly surface so that cables can be led Convectional cooling Operation safety tab 5 Protection class PN EN 60950 1 2007 I first Protection grade PN EN 60529 ...

Page 5: ...s 230VAC to L N terminals of the PSU Connect the ground wire to the terminal marked by the earth symbol Use a three core cable with a yellow and green PE protection wire to make the connection Lead the cables to the appropriate terminals of the connection board through the bushing The shock protection circuit shall be performed with a particular care i e the yellow and green wire coat of the power...

Page 6: ...een chosen replace the fuse of the same parameters in case of a failure 4 2 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures However in case of significant dust level clean its interior with compressed air In case of a fuse exchange use the repla...

Page 7: ...ue to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and transport use that violates the operation manual or equipment s intended...

Reviews: