1.3. Description of PSU components and connectors. 

Table 1.  Elements of the PSU pcb (see fig. 2). 

Element no. 

Description 

[1] 

L1…..L4  (green) LEDs  (indicating fuse activation) 

[2] 

F1…F4 glass fuses in AUX (+) circuits 

[3] 

IN  supply input of the LB4 strip 

[4] 

AUX1…. AUX4 outputs, COM (-) shared terminal 

 

Fig.2. The view of the PSU’s pcb. 

Table 2. Elements of the PSU (see fig. 3). 

Element no. 

Description 

[1] 

L-N  230 V AC power connectors, 

 PE protection connector 

 

[2] 

PSU module 

[3] 

V

ADJ

,  potentiometer,  output voltage adjustment within the range of 12,0V÷15,0V DC 

[4] 

LED indication of DC power status, main module of the PSU 

[5] 

LB4 fuse strip, with power outputs and LED indication 

 

 

 
 

Fig.3. The view of the PSU. 

Summary of Contents for PSDC04122T

Page 1: ...PSDC04122T v 1 0 PSDC 12V 2A 4x0 5A TOPIC Switched mode power supply for CCTV EN Edition 2 from 25 02 2013 Supersedes the 1 from 08 01 2013 edition ...

Page 2: ...ation procedure 3 Operating status indication 3 1 LED indication 4 Operation and use 4 1 Overload or short circuit at the PSU output 4 2Maintenance 1 Technical description 1 1 General description The stabilized PSU PSDC04122T is intended for supplying CCTV devices requiring stabilised voltage of 12V DC The output voltage adjustment range is adjusted via a potentiometer within the range of 12 0V 15...

Page 3: ... of the LB4 strip 4 AUX1 AUX4 outputs COM shared terminal Fig 2 The view of the PSU s pcb Table 2 Elements of the PSU see fig 3 Element no Description 1 L N 230 V AC power connectors PE protection connector 2 PSU module 3 VADJ potentiometer output voltage adjustment within the range of 12 0V 15 0V DC 4 LED indication of DC power status main module of the PSU 5 LB4 fuse strip with power outputs and...

Page 4: ... Enclosure Steel plate DC01 0 7mm colour RAL 9003 Closing Cheese head screw at the front Connectors Power supply 230V AC Φ0 63 2 05 AWG 22 12 AUX outputs Φ0 51 2 05 AWG 24 12 LB4 Φ0 51 2 05 AWG 24 12 Notes The enclosure does not adjoin the assembly surface so that cables can be led Convectional cooling Operation safety tab 5 Protection class PN EN 60950 1 2007 I first Protection grade PN EN 60529 ...

Page 5: ...s 230VAC to L N terminals of the PSU Connect the ground wire to the terminal marked by the earth symbol Use a three core cable with a yellow and green PE protection wire to make the connection Lead the cables to the appropriate terminals of the connection board through the bushing The shock protection circuit shall be performed with a particular care i e the yellow and green wire coat of the power...

Page 6: ...een chosen replace the fuse of the same parameters in case of a failure 4 2 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures However in case of significant dust level clean its interior with compressed air In case of a fuse exchange use the repla...

Page 7: ...ue to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and transport use that violates the operation manual or equipment s intended...