www.pulsar.pl
PSBEN1012B
18
EXT IN technical input
Voltage ’on’ – 10÷30V DC
Voltage ’off’ – 0÷2V DC
Level of galvanic isolation: 1500V
RMS
Optical indication:
- LEDs on the PSU’s pcb,
- LED panel
•
output current readings
•
output voltage readings
•
failure codes with history
Acoustic indication:
- piezoelectric indicator ~75dB /0,3m, switchable via jumper
F
BAT
fuse
F
MAIN
fuse
F 2,0A / 250V
T 0,315A / 250V
Additional accessories (not included)
- interface USB-TTL ‘INTU’; communication: USB-TTL
- interface RS485 ‘INTR’; communication: RS485
- interface USB-RS485 ‘INTUR’; communication: USB-RS485
- interface Ethernet ‘INTE’; communication: Ethernet
- interface WiFi “INTW’; wireless communication: Wi-Fi
- interface RS485-Ethernet “INTRE’; communication: RS485-
Ethernet
- interface RS485-WiFi “INTRW’; wireless communication:
RS485-WiFi
Table 7. Mechanical specifications.
Enclosure dimensions
270 x 250 x 88 (275 x 255 x 80+8) (WxHxD) [mm] (+/- 2)
Fixing
242x 223 x
Φ
6 x4 (WxH)
Fitting battery
7Ah/12V (SLA) max.
Net/gross weight
3,0/3,2kg
Enclosure
Steel plate DC01 1mm, colour RAL 9005 (black)
Closing
Cheese head screw x2 (at the front), lock assembly possible
Connectors
Supply:
Φ
0,63÷2,50 (AWG 22-10)
Outputs :
Ф
0,51÷2 (AWG 24-12), battery outputs BAT: 6,3F-2,5, 30cm
TAMPER output: wires, 25cm
Notes
The enclosure does not adjoin the assembly surface so that cables can be led.
Convectional cooling.
Table 8. Operation safety.
Protection class PN-EN 60950-1:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input (network) circuit and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 M
Ω
, 500V/DC
Table 9. Operating specifications.
Operating temperature
-10ºC...+40ºC
Storage temperature
-20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insolation
unacceptable
Vibrations and impulse waves during transport
PN-83/T-42106
Table 10. PSU’s factory settings.
Indication time of EPS network loss
5s
Battery charging current
0,6A
Battery presence
YES (battery present)
Battery test
YES (activated)
Deep discharge battery protection UVP
YES (battery protected)
Communication address
1
Transmission
19.2k 8E1