Pulsar PSBD 5012 Manual Download Page 7

 

Operation safety (tab.5). 

Protection class PN-EN 60950-1:2004 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between input (network) circuit and output circuits of power-supply (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
500  V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

Operation parameters (tab.6). 

Operation temperature 

-10ºC...+40ºC  

Storage temperature 

+5ºC...+40ºC 

Relative humidity 

30%...90%, without condensation 

Vibrations during operation 

Unacceptable 

Impulse waves during operation 

Unacceptable 

Direct isolation 

Unacceptable 

Vibrations and impulse waves during transport 

According to PN-83/T-42106 

 

2. Installation. 

 

2.1 Requirements. 

The  buffer  power-supply  shall  be  mounted  by  the  qualified  installer  having  appropriate  (required  and 

necessary for a given country) permissions and qualifications for connecting (operating) 230V/AC installations and 
low-voltage  installations.  The  device  shall  be  mounted  in  closed  rooms,  according  to  the  environment  class  II,  of 
the normal air humidity (RH=90% max. without condensation) and the temperature within the range from -10°C to 
+40°C.  The  power-supply  shall  operate  in  a  vertical  position  so  that  free  and  convectional  air  flow  through 
ventilating holes of the casing is guaranteed.  

Before installation  is started, the  balance of the  power-supply  load shall  be performed. During the normal 

operation,  the  sum  of  currents  collected  by  receivers  shall  not  exceed 

I=5A  (P=69W  max.) 

considering  that  the 

maximum battery charging current 

Ibat 

 
As  the  power-supply  is  designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch, 

therefore  an  appropriate  overload  protection  in  the  power  supply  circuit  shall  be  guaranteed.  Moreover,  the  user 
shall  be  informed  about  the  method  of  isolation  of  the  power  supply  from  the  power  voltage  (usually  through 
assignment  and  marking  of  an  appropriate  fuse  in  the  fuse-box).  The  electrical  system  shall  be  made  in 
accordance with valid standards and regulations. 

 
2.2 Installation procedure.

 

1. Before installation is started, the voltage in the 230V power-supply circuit shall be isolated. 

2. The power-supply shall be mounted in a selected location and connection cords shall be lead.  
3. The power cables (~230Vac) shall be connected to L-N terminals of the power supply.  The earth conductor shall 

be connected to the terminal marked by the earth symbol 

. The connection shall be made by means of a three-

core cable (with a yellow and green PE protection wire). The power cables shall be lead to appropriate terminals of 
the connection board through bushing. 

 

The circuit of the shock protection shall be performed with a particular care, i.e. the yellow and 
green  protection  wire  of  the  power  cable  shall  be  connected  from  one  side  to  the  terminal 
marked by the symbol of 

  in the casing of the power-supply. Operation of the power-supply 

without  the  properly  made  and  fully  operational  circuit  of  the  shock  protection  is 
UNACCEPTABLE! It can result in failure of devices and electric shock.

  

 

 
4. Connect the conductors of consumers to the +AU, -AUX terminals of the terminal box on the power-supply unit. 
5. If necessary, connect the conductors from the equipment to the technical outputs:  
 - BS AC status indication (alarm panel, controller, signaling unit, LED diode, etc.) 
 - AW technical output of operation status of the power supply 

 

- TAMPER signalization of power-supply unit opening 

6. Using the dip switch 

‘J1’

‘J2’

 determine maximal battery charging current, take into consideration battery 

parameters. 

Summary of Contents for PSBD 5012

Page 1: ...PSU B 13 8V S 5A 1 EL TR 40Ah MC PSBD 5012 v 1 1 Buffer switching power supply unit EN Edition 2 from the 21 st June 2010 Supercedes edition 1 from the 21 st April 2009...

Page 2: ...it with the total current capacity 5A and output voltage 11 0V 13 8V Equipped with the AC supply absence indication system battery assisted operation failure and casing sabotage indication system Meta...

Page 3: ...ration 2 x converter DC DC 2 5A 5V ADC 255 2 x LB5 AW fuse block AWZ 536 40Ah 2 x voltage reducer RN 2 5A 12V RN250 2 x LB5 AW fuse block AWZ 536 40Ah 1 x voltage reducer RN 5 0A 12V RN500 2 x LB5 AW...

Page 4: ...5A J1 J2 Ibat 2 0A Legend dip switch installed dip switch removed 8 BAT BAT outputs battery connectors BAT red BAT black 9 TAMPER x2 microswitches contacts contact of antisabotage protection NC 10 F2...

Page 5: ...5 Fig 2 The view of the power supply...

Page 6: ...attery circuit SCP and reverse polarity protection 6 3A current limitation F1 fuse failure requires replace of the fuse element Excessive discharge protection UVP U 10 0 V 5 disconnection of BAT batte...

Page 7: ...and is not equipped with a power switch therefore an appropriate overload protection in the power supply circuit shall be guaranteed Moreover the user shall be informed about the method of isolation o...

Page 8: ...of illumination is dependent on the charging current AUX green diode indicates the DC supply status at the output of the PSU Under normal status the diode is permanently illuminated and in the case o...

Page 9: ...he PSU is equipped with the discharged battery disconnection system UPV the configuration of functions through the dip switch JP B The battery protection is on if the dip switch JP B is removed 4 3 Ma...

Page 10: ...ing of the equipment to the service centre of the manufacturer 7 The repair period mentioned in item 5 may be prolonged if there is no technical capability to carry out the repairs and in the case tha...

Reviews: