Pulsar PSBD 5012 Manual Download Page 10

 

10 

 

 

 

 

 

 

 

 

WEEE MARK 

 
The waste electric and electronic products do not mix with general household waste. 
There  are  separate  collection  system  for  used  electric  and  electronic  products  in 
accordance with legislation under the WEEE Directive and is effective only with EU. 

 
 
 

 

Notice: 

The power supply unit is adapted for cooperation with the sealed lead-acid battery (SLA). After the 

operation period it must not be thrown but recycled according to the applicable law. 

 

 

 

GENERAL WARRANTY CONDITIONS 

1. Pulsar K. Bogusz Sp.j. (manufacturer) grants a two-year quality warranty for the equipment, starting from the date of purchase 
placed on the purchase order.  
2. Should such purchase order be missing when the claim is submitted, the three-year guarantee period is counted from the date 
of the manufacturing of the device.  
3. The warranty includes free-of-charge repairing or replacing with a functional equivalent (the selection is made by the 
manufacturer) of the malfunctioning device, due to reasons attributable to the manufacturer, including manufacturing and 
material defects, unless such defects have been reported beyond the warranty period (item 1 and 2).  
4. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the 
manufacturer.  
5. The warranty applies to complete equipment, including the type of defect specified in writing, using a properly filled warranty 
claim.   
6. Should the claim be accepted, the manufacturer is obliged to render warranty repairs, as soon as possible, however not later 
that within 14 days from the delivering of the equipment to the service centre of the manufacturer.  
7. The repair period mentioned in item 5 may be prolonged, if there is no technical capability to carry out the repairs, and in the 
case that the equipment has been accepted conditionally, due to the failing of the warranty terms by the claimant.  
8. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.  
9. The warranty does not cover the defects of the equipment, resulting from: 
- reasons beyond the manufacturer's control, 
- mechanical damage, 
- improper storage and transport, 
- use that violates the operation manual or equipment application,  
- random events, including lightning discharges, failures of power networks, fire, flooding, high temperatures and chemical 
agents,  
- improper installation and configuration (at variance with the rules set forth in the manual), 
10. Each confirmation of structural modifications or repairs, carried out beyond the service centre of the manufacturer, or any 
modification of serial numbers or warranty labels, results in the loss of the rights resulting from the warranty. 
11. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the 
wholesale prices suggested by the manufacturer on the day of purchase.  
12. The manufacturer shall not be responsible for the defects that resulted from the damaging, malfunctioning or inability to 
operate the equipment, particularly, if such defects are the result of failing to abide by the recommendations and requirements 
contained in the manual, or the use of the equipment.  

 

Pulsar K.Bogusz Sp.j.  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

 

 

Summary of Contents for PSBD 5012

Page 1: ...PSU B 13 8V S 5A 1 EL TR 40Ah MC PSBD 5012 v 1 1 Buffer switching power supply unit EN Edition 2 from the 21 st June 2010 Supercedes edition 1 from the 21 st April 2009...

Page 2: ...it with the total current capacity 5A and output voltage 11 0V 13 8V Equipped with the AC supply absence indication system battery assisted operation failure and casing sabotage indication system Meta...

Page 3: ...ration 2 x converter DC DC 2 5A 5V ADC 255 2 x LB5 AW fuse block AWZ 536 40Ah 2 x voltage reducer RN 2 5A 12V RN250 2 x LB5 AW fuse block AWZ 536 40Ah 1 x voltage reducer RN 5 0A 12V RN500 2 x LB5 AW...

Page 4: ...5A J1 J2 Ibat 2 0A Legend dip switch installed dip switch removed 8 BAT BAT outputs battery connectors BAT red BAT black 9 TAMPER x2 microswitches contacts contact of antisabotage protection NC 10 F2...

Page 5: ...5 Fig 2 The view of the power supply...

Page 6: ...attery circuit SCP and reverse polarity protection 6 3A current limitation F1 fuse failure requires replace of the fuse element Excessive discharge protection UVP U 10 0 V 5 disconnection of BAT batte...

Page 7: ...and is not equipped with a power switch therefore an appropriate overload protection in the power supply circuit shall be guaranteed Moreover the user shall be informed about the method of isolation o...

Page 8: ...of illumination is dependent on the charging current AUX green diode indicates the DC supply status at the output of the PSU Under normal status the diode is permanently illuminated and in the case o...

Page 9: ...he PSU is equipped with the discharged battery disconnection system UPV the configuration of functions through the dip switch JP B The battery protection is on if the dip switch JP B is removed 4 3 Ma...

Page 10: ...ing of the equipment to the service centre of the manufacturer 7 The repair period mentioned in item 5 may be prolonged if there is no technical capability to carry out the repairs and in the case tha...

Reviews: