1.3. Description of elements and connection links of the power-supply unit  (tab.1, tab.2, fig.2). 

Table 1. 

Element no. 

[Fig. 2] 

Description 

[1] 

F1 

fuse in the battery circuit

 

[2] 

START

 pushbutton (power activation without AC supply) 

[3] 

JP-B,  dip switch 

- configuration of UVP battery protection function 

 

JP-B = 

  protection function (disconnection) of the battery off 

 

JP-B = 

  protection function (disconnection) of the battery on 

 

Legend:

 

  

dip switch installed 

  dip switch removed 

[4] 

P1

 potentiometer, voltage adjustment 

[5] 

OUTPUTS 

connector (Tab.2)

 

[6] 

AC, LB, AUX 

optical indication of the power-supply unit operation 

[7] 

J1, J2  dip switch 

– battery charging current configuration 

 

J1= 

  J2= 

   Ibat =0,3A 

 

J1= 

  J2= 

   Ibat =0,9A 

 

J1= 

  J2= 

   Ibat =1,5A 

 

J1= 

  J2= 

   Ibat =2,0A 

 

Legend:

 

  

dip switch installed 

  dip switch removed 

[8] 

BAT+/BAT-:  

outputs, battery connBAT=red, - BAT=black 

[9] 

TAMPER x2,  

microswitches (contacts) contact of antisabotage protection

 (NC) 

[10] 

F2 

witch in the Power supply circuit (230V/AC) 

[11] 

 L-N  

power-supply connector 

230V/AC, 

 

PE protection connector

 

 

[12] 

Connector to an external optical signalization: AC and AUX. 

Tab.1. The elements of the power-supply unit.

 

Table 2. 

[5] 

Description of power-supply unit outputs 

~AC~ 

AC supply input 

+BAT 

-BAT 

DC supply output of the battery 
(+BAT= red, -BAT=black) 

+AUX 

-AUX 

DC supply output 
(+AUX= +U, -AUX=GND) 

  BS 

AC absence technical output –OC type 
   level hi-Z = state: AC power supply 
   level L = state: AC power supply failure 

  AW 

Technical output of voltage converter (regulator) operation status: 
PWR OK –OC type 
   level hiZ = state: failure, overload 
   level L = state: normal operation 

Tab.2. Output terminals of the power-supply unit. 

 
 

Summary of Contents for PSBD 5012

Page 1: ...PSU B 13 8V S 5A 1 EL TR 40Ah MC PSBD 5012 v 1 1 Buffer switching power supply unit EN Edition 2 from the 21 st June 2010 Supercedes edition 1 from the 21 st April 2009...

Page 2: ...it with the total current capacity 5A and output voltage 11 0V 13 8V Equipped with the AC supply absence indication system battery assisted operation failure and casing sabotage indication system Meta...

Page 3: ...ration 2 x converter DC DC 2 5A 5V ADC 255 2 x LB5 AW fuse block AWZ 536 40Ah 2 x voltage reducer RN 2 5A 12V RN250 2 x LB5 AW fuse block AWZ 536 40Ah 1 x voltage reducer RN 5 0A 12V RN500 2 x LB5 AW...

Page 4: ...5A J1 J2 Ibat 2 0A Legend dip switch installed dip switch removed 8 BAT BAT outputs battery connectors BAT red BAT black 9 TAMPER x2 microswitches contacts contact of antisabotage protection NC 10 F2...

Page 5: ...5 Fig 2 The view of the power supply...

Page 6: ...attery circuit SCP and reverse polarity protection 6 3A current limitation F1 fuse failure requires replace of the fuse element Excessive discharge protection UVP U 10 0 V 5 disconnection of BAT batte...

Page 7: ...and is not equipped with a power switch therefore an appropriate overload protection in the power supply circuit shall be guaranteed Moreover the user shall be informed about the method of isolation o...

Page 8: ...of illumination is dependent on the charging current AUX green diode indicates the DC supply status at the output of the PSU Under normal status the diode is permanently illuminated and in the case o...

Page 9: ...he PSU is equipped with the discharged battery disconnection system UPV the configuration of functions through the dip switch JP B The battery protection is on if the dip switch JP B is removed 4 3 Ma...

Page 10: ...ing of the equipment to the service centre of the manufacturer 7 The repair period mentioned in item 5 may be prolonged if there is no technical capability to carry out the repairs and in the case tha...

Reviews: