4.2 Battery assisted operation.  

In the case of power failure, in the unit will instantly switch to the battery assisted operation.

 

In order to activate the operation of the PSU    from the battery itself, connect the BAT connectors in accordance 
with the indications: +BAT red to ‘plus’ and, -BAT black to 'minus’ of the battery and press and keep depressed for 
five seconds the START pushbutton on the equipment board. 

The  PSU  is  equipped  with  the  discharged  battery  disconnection  system;  the  configuration  of 
functions  through  the  jumper  ‘A’.  The  battery  protection  is  on  if  the  jumper  ‘A’  is  removed.

 

 
 

4.3 Maintenance. 

Any  and  all  maintenance  operations  may  be  performed  following  the  disconnection  of  the  PSU  from  the 

power supply network. The PSU   does not require performing any specific maintenance measures, however, in the 
case  of  significant  dust  rate,  its  interior  is  recommended  to  be  cleaned  with  compressed  air.  In  the  case  of  fuse 
replacement, only the substitutes in conformity to the original ones are allowed. 

 

 

 

 
 
 
 
 
 

 

WEEE MARK 

 

The used electric and electronic products, do not mix with general household 

waste. There are separate collection system for used electric and electronic 

products in accordance with legislation under the WEEE Directive and is effective 

only with EU. 

 

 

 
 
 
 

 

 

 

 

WARRANTY 

24 months since the sale date, 36 months since the production date. 

THE WARRANTY IS VALID ONLY after presenting the invoice of the sale to which the claim refers.

 

Pulsar K.Bogusz Sp.j.  

Siedlec 150,  

32-744 Łapczyca, Polska 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

 

 

Summary of Contents for PSBBH 1012

Page 1: ...PSU B 13 8V S 1 0A 1 EL TR 7Ah HC PSBBH 1012 v 2 0 Buffer switching power supply unit in the ABS IP65 casing EN Edition 3 from the 17 th March 2011 Supercedes edition 2 from the 30 th March 2009...

Page 2: ...pace for 12V 1 2Ah or 7Ah battery horizontal or vertical position depending on configuration The casing features a microswitch indicating door front opening Information about additional equipment for...

Page 3: ...umper installed jumper removed 2 START pushbutton power activation without AC supply 3 P1 potentiometer voltage adjustment 4 F1 fuse in the battery circuit 5 AC LB AUX optical indication of the power...

Page 4: ...tery BAT red BAT black AUX AUX DC supply output AUX U AUX GND COM NC NO Technical output of AC absence relay assisted COM common contact NC normally closed contact without AC supply NO normally opened...

Page 5: ...uires replacement of the fuse element Overvoltage protection OVP U 22V varistor automatically recovered Excessive discharge protection UVP U 10 0 V 5 disconnection of BAT battery Technical outputs COM...

Page 6: ...osition Before installation is started the balance of the power supply load shall be performed During the normal operation the sum of currents collected by receivers shall not exceed I 1 0A P 14W max...

Page 7: ...tion indication 3 1 Optical indication The PSU is equipped with three diodes indicating operation status AC LB AUX placed on the PCB of the power supply unit AC red diode under normal status AC supply...

Page 8: ...U from the power supply network The PSU does not require performing any specific maintenance measures however in the case of significant dust rate its interior is recommended to be cleaned with compre...