GREY POWER plus

  

 

 

W

H

D

Output current 

- for grades 1, 2: 
     

Io = 1,1A +  0,9A battery charging current 

- for general use: 
 

Io = 2A (without a battery) 

     

Io = 1,6A + 0,4A battery charging current 

             Io = 1,1A + 0,9A battery charging current

 

Output voltage adjustment range 

11÷14,5V DC 

Ripple voltage 

20mV p-p 

Current consumption by PSU systems 

15 mA max. 

Battery charging current 

0,4A/0,9A jumper selectable 

Short-circuit protection SCP  

200% ÷ 250% of PSU power - current limitation and/or fuse F

BAT

 

damage in the battery circuit (fuse-element replacement 
required) 
Automatic return 

Overload protection OLP 

110%  ÷  150%  (@25ºC÷65ºC)  of  PSU  power  -  limitation  by  the 
PTC  resettable  fuse,  manual  restart  (disconnection  of  the  DC 
output circuit) 

Battery circuit protection SCP and reverse 
polarity connection 

F3,15A- current limitation, F

BAT

 fuse (in case of a failure, fuse-

element replacement required) 

Surge protection 

varistors 

Overvoltage protection OVP 

U>16,5V 

disconnection 

of 

the 

output 

voltage 

(AUX+ 

disconnection), automatic return 
U> 14,5V fault indication 

Deep discharge battery protection UVP 

U<10V (± 0,5V) – disconnection of battery terminal 

Tamper protection: 
- TAMPER - indicates unwanted opening of the 
enclosure 

 
- microswitch, NC contacts (enclosure closed), 0,5A@50V DC 
(max.) 

Technical outputs: 
- EPS; output indicating AC power failure 
 
 
 
 
- PSU; output indicating no DC power/PSU failure  
 
 
 
- APS; output indicating battery failure 

 
-  OC type: 50mA max.  
 

Normal operation: L state (0V), 

 

failure: hi-Z state, 

- delay time 0s

÷1h (+/-20%) – jumper selectable 

T

AC

  

 
- OC type: 50mA max.  
 

Normal operation: L state (0V), 

 

failure: hi-Z state,  

 
- OC type, 50mA max.  
 

Normal operation: L state (0V), 

 

failure:  hi-Z state 

LED indication 

LEDs: AC/DC power status, failure 

Acoustic indication 

piezoelectric indicator 75dB/0,3m, switchable via jumper 

Fuses:  
 

- F

MAINS

  

 

- F

BAT

 

 
T 500mA / 250V  
F 3,15A / 250V 

Table 4. Mechanical specifications. 

Dimensions 

W=230 H=300 D+D

1

=92+8 mm [+/- 2 mm] 

W

1

=235, H

1

=305 [+/- 2 mm]

 

Fixing 

See Fig., 3 

Fitting battery  

17Ah/12V (SLA) max. 
180x165x85mm (WxHxD) max  

Net/gross weight 

3 / 3,2 kg 

Enclosure  

Steel plate DC01, thickness: 0,7mm, colour: RAL 9003 

Closing 

Cheese head screw (at the front) 

Terminals 

Mains supply 230V AC: 

Ф0,51÷2,05 (AWG 24-12), 0,5÷1,5mm

2

 

Outputs: Ф0,51÷2,05 (AWG 24-12), 0,5÷1,5mm

2

 

BAT battery outputs: 6,3F-0,5, 30cm 

Notes 

The enclosure does not adjoin the assembly surface so that cables can be led. 

 

 

 

Summary of Contents for GREY POWER plus AWZ 222

Page 1: ...AWZ 222 v 2 3 AWZ 13 8V 2A 17Ah LM Linear buffer power supply unit Grade 2 EN Edition 9 from 02 11 2017 Supercedes the edition 8 from 23 01 2017 GREY POWER plus...

Page 2: ...er failure protections SCP short circuit protection OLP overload protection over voltage protection OHP overheat protection surge protection against sabotage warranty 5 years from the production date...

Page 3: ...battery space for a 17Ah 12V battery It is fitted with micro switches indicating unwanted door opening front panel The power supply is pre configured for use in alarm systems stage 1 and 2 in accorda...

Page 4: ...VP optical indication for activating the over voltage system FBAT fuse in the battery circuit F3 15A 250V Terminals TAMPER antisabotage protection microswitch connector APS technical output indicating...

Page 5: ...500mA 250V Battery connectors BAT red BAT black Fig 3 The view of the PSU 1 4 Specifications electrical specifications tab 3 mechanical specifications tab 4 operation safety tab 5 operating specificat...

Page 6: ...ery protection UVP U 10V 0 5V disconnection of battery terminal Tamper protection TAMPER indicates unwanted opening of the enclosure microswitch NC contacts enclosure closed 0 5A 50V DC max Technical...

Page 7: ...ng an appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure Caution Before installation make sure that the voltage in the 230V...

Page 8: ...e EPS FLT technical output after some time determined by TAC pins battery disconnection LED indication acoustic indication and the APS FLT technical output after a battery test have been completed 10m...

Page 9: ...e lag T 0s J1 J2 time lag T 5min J1 J2 time lag T 1h J1 J2 time lag T 6h PSU FLT output indicating PSU failure The output indicates PSU failure Under normal status correct operation the output is shor...

Page 10: ...board and hold for 3s Disconnecting the PSU from the battery press the STOP button on the main board and hold for 3s 4 2 Deep discharge battery protection UVP The PSU is equipped with the disconnectio...

Page 11: ...e below shows how long does it take to charge a fully discharged battery up to min 80 of its nominal capacity Table 9 Battery charging time 17Ah battery charging time up to the capacity of 0 8 C Charg...

Page 12: ...l waste and to collect such WEEE separately The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the appl...

Reviews: