background image

www.pulsar.pl                                                           AWZ222                                                   

GREY POWER plus

  

 

 

 

 

 

Caption: 

 jumper on, 

  jumper off 

 

STOP

 button (disconnects the power supply from the battery or enables / disables the 

battery test) 

 

Connectors ~AC~   

– AC power input

 

 

START

 button (launching the PSU from a battery) 

 

 

– pin; activation of the acoustic indication 

       

 - indication on 

        

 - indication off 

 

 

 

Caption: 

 jumper on, 

  jumper off 

 

V

ADJ 

 - potentiometer,

 

DC voltage adjustment 

DC 12 ÷ 14,5V 

 

BUZZER 

– acoustic indicator

 

 

LB  

– LED battery charging indication 

 

RED DIODE 

LED indication 

 

GREEN DIODE 

LED indication 

 

OVP  

– optical indication for activating the over voltage system

 

 

F

BAT

  

– fuse in the battery circuit, F3,15A / 250V 

 

Terminals: 
TAMPER 

– antisabotage protection microswitch connector

 

APS     

– technical output indicating battery failure 

 

 

hi-Z state 

= battery failure - O.K. 

 

 

0V state  

= battery O.K. 

EPS 

– technical output of AC power failure indication 

 

 

hi-Z state 

= AC power failure 

 

 

 

0V state  

= AC power - O.K. 

PSU

  

– technical output of PSU failure indication 

 

 

hi-Z state 

= failure 

 

 

0V state  

= PSU status O.K.

  

+AUX-  

– DC power output, (+AUX= +U, -AUX=GND) 

Description: hi-Z 

– high impedance, 0V – connection to the ground GND 

 

I

BAT 

Jumper; 

- battery charging current configuration 

 

I

BAT

 = 

,  Ibat =0,4 A 

 

I

BAT

 = 

,  Ibat =0,9 A 

 

Description: 

 jumper on, 

  jumper off

 

 
 

 

 

Fig. 2. The view of the PSU pcb. 

 

Summary of Contents for GREY POWER plus AWZ 222

Page 1: ...AWZ 222 v 2 3 AWZ 13 8V 2A 17Ah LM Linear buffer power supply unit Grade 2 EN Edition 9 from 02 11 2017 Supercedes the edition 8 from 23 01 2017 GREY POWER plus...

Page 2: ...er failure protections SCP short circuit protection OLP overload protection over voltage protection OHP overheat protection surge protection against sabotage warranty 5 years from the production date...

Page 3: ...battery space for a 17Ah 12V battery It is fitted with micro switches indicating unwanted door opening front panel The power supply is pre configured for use in alarm systems stage 1 and 2 in accorda...

Page 4: ...VP optical indication for activating the over voltage system FBAT fuse in the battery circuit F3 15A 250V Terminals TAMPER antisabotage protection microswitch connector APS technical output indicating...

Page 5: ...500mA 250V Battery connectors BAT red BAT black Fig 3 The view of the PSU 1 4 Specifications electrical specifications tab 3 mechanical specifications tab 4 operation safety tab 5 operating specificat...

Page 6: ...ery protection UVP U 10V 0 5V disconnection of battery terminal Tamper protection TAMPER indicates unwanted opening of the enclosure microswitch NC contacts enclosure closed 0 5A 50V DC max Technical...

Page 7: ...ng an appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure Caution Before installation make sure that the voltage in the 230V...

Page 8: ...e EPS FLT technical output after some time determined by TAC pins battery disconnection LED indication acoustic indication and the APS FLT technical output after a battery test have been completed 10m...

Page 9: ...e lag T 0s J1 J2 time lag T 5min J1 J2 time lag T 1h J1 J2 time lag T 6h PSU FLT output indicating PSU failure The output indicates PSU failure Under normal status correct operation the output is shor...

Page 10: ...board and hold for 3s Disconnecting the PSU from the battery press the STOP button on the main board and hold for 3s 4 2 Deep discharge battery protection UVP The PSU is equipped with the disconnectio...

Page 11: ...e below shows how long does it take to charge a fully discharged battery up to min 80 of its nominal capacity Table 9 Battery charging time 17Ah battery charging time up to the capacity of 0 8 C Charg...

Page 12: ...l waste and to collect such WEEE separately The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the appl...