PULSAR MEASUREMENT
9
Product Specification
PHYSICAL
Dimensions & Mounting
dBi3:
77mm dia x 134mm high (3 x 5.31 inch) Rear
thread 1” BSP/NPT
dBi6 & dBi10:
86mm dia x 121 high (3.38 x 4.75 inch).
Rear thread 1” BSP/NPT
dBi15:
86mm dia x 134 mm high (3.38 x 5.32 inch). Rear
1” BSP/NPT
Weight
dBi3:
1kg (2.2lbs),
dBi6:
1.2kg (2.7lbs)
dBi10:
1.3kg (2.9lbs),
dBi15:
1.4kg (3.1lbs)
Enclosure material/description
Valox 357
Transducer cable requirements
2 core screened. Integral cable length 5, 10, 20 or 30m
ENVIRONMENTAL
Enclosure protection (all models)
IP68
Temperature Compensation
Internal temperature sensor, ± 0.5
o
C
Max. & min. temperature
(electronics)
-40 ºC to +80 ºC (-40ºF to 176ºF)
CE Approval
See EU Declaration of Conformity
ATEX
II 1 G Ex ia IIC T4 Ga, II 1 D Ex ia IIIC T130
O
C
Da Tamb -40
o
C to +80
o
C
II 2 E Ex mb IIC T4 Gb, II 2 D Exmb IIIC
T130
o
C Db Tamb -40
o
C to +80
o
C
PERFORMANCE
Measurement Range
dBi3:
0.125m (0.41 ft.) to 3.00m (9.84 ft.)
dBi6:
0.3m (0.98 ft.) to 6.00m (19.69 ft.)
dBi10:
0.3m (0.98 ft.) to 10.00m (32.81ft.)
dBi15:
0.5m (1.64 ft.) to 15.00m (49.213 ft.)
Accuracy/Repeatability
dBi3:
2mm (0.08 inch)
dBi6:
4mm (0.16 inch)
dBi10:
3mm (0.12 inch) up to 6m (20ft.) range
6mm (0.24 inch) over 6m range
dBi15:
5mm (0.2 inch) up to 10m (33ft.) range
10mm (0.39 inch) over 10m range
Frequency
dBi3
: 125kHz
dBi6
: 75kHz
dBi10
: 50kHz
dBi15
: 41kHz
Beam Angle
dBi3, dBi6 & dBi10: <10
o
Summary of Contents for dBi 10
Page 2: ...2...
Page 11: ...PULSAR MEASUREMENT 11 EU Declaration of Conformity...
Page 23: ...PULSAR MEASUREMENT 23...
Page 24: ...DBI HART INSTRUCTION MANUAL 24...