Live, Neutral and Earth Outputs:

 Terminal blocks are provided for 

connection to your lamps etc.   Two terminals are provided for each 
live output. 

Important: 

 with 3 phase delta supply use the correct neutral terminal 

block - see Front Panel printing for channel numbers.  

SIGNAL CONNECTIONS

 

may be made by either using the sockets 

provided (8 pin DIN / 5 pin XLR) or by hardwiring

.

 

Analogue Control Signals:

  One 8 pin DIN socket is provided for 

each six channels.   The pin connections are: 

Pin 1 =

 

Low Voltage Supply Out 

Pin 5  = Channel 3/  9/15

Pin 2 =

 

Chassis Earth 

Pin 6  = Channel 4/10/16

Pin 3 =

 

Channel 1/7/13 

Pin 7  = Channel 5/11/17

Pin 4 =

 

Channel 2/8/14 

Pin 8  = Channel 6/12/18

For hardwiring, the connections to the terminal blocks are indicated 
on the Front Panel and the PCB. 

Digital Control Signals: 

 Two 5 pin XLR sockets (in / thru) and 

two 3 way terminal blocks are provided for the digital inputs.  The pin 
connections are: 

For hardwiring, the connections to the terminal blocks are indicated 
on the Front Panel and the PCB. 

Note: 

 Pins 4 and 5 are occasionally used by other manufacturers for 

data.  We recommend the use of 2 core plus screen cable, leaving 
pins 4 and 5 open circuit, to connect to this type of equipment.  
However, the Low Voltage Supply on pin 5 of the male XLR is 
limited to cause no harm to such equipment. 

Technical Details: 

 

0V 

=  Off 

(Dimming and Switching Datapaks) 

 >+3V 

=  Full On  (Switching Datapaks) 

 +10V 

=  Full On  (Dimming Datapaks) 

 The input impedance is 100k ohms. 

 

The Low Voltage Supply (LVS)

 available for a Controller from pin 

1 of the DIN sockets or pin 5 of the XLR male chassis connector is 
+18...25VDC at up to 120mA. 

 Analogue control cables do not need to be screened as the inputs 

of the Datapak are filtered against hum and interference. 

 The cables may be as long as necessary and the minimum size of 

their conductors is limited only by considerations of mechanical 
strength. 

The internal controls and indicators are only to be operated by 
suitably skilled and competent persons. 

Digital Start Address Select and Test Switches:

  The digital start 

address is the sum of the numbers produced by the selected 
switches - see examples on Front Panel.   The Test Switch provides 
a block of three channels moving through the Datapak channels. 

Digital Input LEDs (Red):

 There are four LEDs provided, the 

RX

 

LED shows when data is being received, the 

ERR

 LED indicates an 

ERRor in the received data, and the 

PMX

  (

P

ulsar 

M

ultiple

X

 using 

RS232/423) and 

DMX

 LEDs show the type of data being received by 

the Datapak.   The software automatically recognises both 

PMX

 and 

DMX

Normal/Full-On Channel Test Switches:

  One per channel.   The 

switches should be in the "Norm" position for control from a desk.   
Use the "Full On" position for testing and diagnostics without having 
to connect a desk. 

Output Monitor LEDs (Green):

  One per channel, indicating it's 

status before the output circuitry (triac, choke etc.).   Thus it may be 
used in conjunction with the 

Output Monitor Neon 

to indicate the 

location of a possible fault.   If it fails to light when the appropriate 

Channel Test Switch

 is set to full then there will be a fault in the 

electronics or the input may be shorted.   If it lights but the 

Output 

Monitor Neon

 does not then there will be a fault in the output 

circuitry. 

Resistive / Inductive Loads:

  All Datapak III models will work with a 

resistive, inductive, or mixed load. 

Dimming / Switching Datapaks ONLY 

Dimming / Switching Switches

 may be set to 

(Dimming) or 

(Switching) for each channel. 

Capacitive Loads

 may be 

S

witched but not 

D

immed. 

If a channel fails to light, a fuse may have blown.   These fuses 
normally only blow if the output is overloaded.   Do not exceed the 
maximum load stated on the Front Panel per channel and do not 
short circuit the outputs.   We recommend that you check your 
lighting equipment regularly for damaged wiring, loose connections 
and potential short circuits.   If a fuse blows, locate and rectify the 
fault before replacing it. 

Channel Fuses:

 If a channel fuse blows, isolate the Datapak from 

the supply, then locate and rectify the fault in the lighting system 
before changing it.   

Important 

- Only the type of fuse specified on 

the front panel may be used - other types will not protect the triacs. 

Electronics Fuse:

 Failure indicates an internal fault and servicing by 

a qualified engineer will be required. 

 

PMX SIGNAL AND LV SUPPLY  DMX SIGNAL AND LV SUPPLY

Pin 1  =

 

 

Chassis Earth - Screen  Pin 1  =  

Chassis Earth - Screen

Pin 2  =

 

Signal 

Pin 2  = Signal - 

Pin 3  =

 

Signal Earth 

Pin 3  =  

Pin 4  =

 

no connection 

Pin 4  = no connection 

Pin 5  = Low Voltage Supply Out 

Pin 5  = Low Voltage Supply Out 

 

 male XLR only 

 

 male XLR only 

CONNECTIONS 

cont.

 

INTERNAL CONTROLS AND

 

INDICATORS 

FUSES 