MANUFACTURER’S PRODUCT WARRANTY 

 

The manufacturer warrants its equipment of its manufacture to be free of defects in material or workmanship. Liability 
under this policy extends for twenty-four (24) months from the date of purchase or one (1) year from date of installation or 
whichever comes first. The manufacturer’s liability is limited to repair or replacement of any device or part which is 
returned, prepaid, to the factory and which is proven defective upon examination. This warranty does not include 
installation or repair cost and in no event shall the manufacturer’s liability exceed its selling price of such part.  
 
The manufacturer disclaims all liability for damage to its products through improper installation, maintenance, use or 
attempts to operate such products beyond their functional capacity, intentionally or otherwise, or any unauthorized repair. 
Replaceable elastomeric parts are expendable and are not covered by any warranty either expressed or implied. The 
manufacturer is not responsible for consequential or other damages, injuries or expense incurred through use of its 
products.  
 
The above warranty is in lieu of any other warranty, either expressed or implied. The manufacturer makes no warranty of 
fitness or merchantability. No agent of ours is authorized to make any warranty other than the above.  

 
For warranty and service matters within the European Union, contact the seller first or:  
 

Pulsafeeder, Inc. Europe 

Units 12 and 13, Edison Road 

Highfield Industrial Estates 

Eastbourne, East Sussex BN23 6PT 

 

 

 

 

 

PRECAUTIONS FOR OPERATION 

 

Each Series 100/150 chemical feeder has been tested to meet prescribed specifications and certain safety standards. 
However, a few precautionary notes should be adhered to at all times. THOROUGHLY READ ALL CAUTIONS PRIOR TO 
INSTALLING METERING PUMP.  
 

 

 

1.  Chemicals used may be dangerous and should be used carefully and according to warnings on the label. Follow 

the directions given with each type of chemical. Do not assume chemicals are the same because they look alike. 
Always store chemicals in a safe location away from children and others. We cannot be responsible for the 
misuse of chemicals being fed by the pump.  

2.  Always wear protective clothing (protective gloves and safety glasses) when working on or near chemical 

metering pumps.  

3.  Tampering with electrical devices can be potentially hazardous. Always place chemicals and feeder installation 

well out of the reach of children and others.  

4.  Be careful to check that the voltage of the installation matches the voltage indicated on the specification label. 

Each pump is equipped with a three prong plug. Whether plugging into a receptacle or wiring into a system, 
always be sure the feeder is grounded. If receptacle is utilized, to disconnect, do not pull wire but grip the plug 
with fingers and pull out.  

5.  Never repair or move the metering pump while operating. Always disconnect electrical current. Before handling 

the pump always allow sufficient time for the motor housing to cool off. Handling the pump too soon after 
shutdown may cause hand burns. For safety use protective gloves.  

6.  All pumps are pretested with water before shipment. Remove head and dry thoroughly if you are pumping a 

material that will react with water, (e.g. sulfuric acid). Valve seats, ball checks, gaskets, and diaphragm should 
also be dried. Before placing feeder into service, extreme care should be taken to follow this procedure.  

7.  Arrows on the pump head and injection fitting indicate chemical flow. When properly installed, these arrows 

should be pointing upward.  

8.  When metering hazardous material DO NOT use plastic tubing. Strictly use proper rigid pipe. Consult supplier for 

special adaptors.  

9. 

Pump is NOT to be used to handle or meter flammable liquids or materials. 

 

Summary of Contents for Chem-Tech 100 Series

Page 1: ...READ ALL CAUTIONS CAREFULLY BEFORE INSTALLING PUMP INSTRUCTION MANUAL P N 32040 Rev C...

Page 2: ...conditioning specialists when treating potable water Always depressurize system prior to installation or disconnecting the metering pump tubing If injection point is lower than the chemical tank and...

Page 3: ...INSTALLING METERING PUMP 1 Chemicals used may be dangerous and should be used carefully and according to warnings on the label Follow the directions given with each type of chemical Do not assume chem...

Page 4: ...TING The carton should contain Metering Pump 4 ft 1 21 m Clear Flexible Suction Tubing 4 ft 1 21 m Stiff White Return Tubing Feeder can be mounted on a wall shelf bracket Figure B tank stand platform...

Page 5: ...manually filled or an approved means must be used to prevent a cross connection between the chemical tank contents and the potable water line Check local plumbing regulations CHEMICAL INJECTION Chemi...

Page 6: ...BAR install a pressure relief valve on the discharge side of the pump head Once the pressure reaches a certain level the pre set relief valve will return the solution being pumped back to the solution...

Page 7: ...ead POINT OF INJECTION Pipe corrosion can result if dillution at the injection point does not occur rapidly This problem is easily prevented by observing this simple rule install injection fitting so...

Page 8: ...site A test for chemical residual in the treated water is the best indication of the correct pump setting MAINTENANCE SCALE GASKETS AND CHECK VALVES When checking the metering pump or providing routi...

Page 9: ...wise Figure O 4 A new pump head or diaphragm should be installed if either is broken or cracked see parts list at the end of this manual The new pump head can be installed by going through the above s...

Page 10: ...head Also chemical incompatibility can cause cracking and subsequent leakage 7 While pump is running turn bleed valve adjustment screw counter clockwise until air is purged Close bleed valve PUMP LOSE...