ML50.100, ML50.109
MiniLine
24V, 2.1A, S
INGLE
P
HASE
I
NPUT
Mar. 2007 / Rev. 1.0 DS-ML50.100-EN
All parameters are specified at 24V, 2.1A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
3/20
5. AC-I
NPUT
AC
input
nom.
AC 100-240V
Wide-range input, TN-, TT-, IT-Mains, see
Fig. 5-1
AC input range
85-264Vac Continuous
operation
60-85Vac
Full power for 200ms, no damage between 0 and 85Vac
264-300Vac <
0.5s
Input
frequency
nom.
50 – 60Hz
±6%
Turn-on
voltage
typ.
65Vac
Steady-state value, see
Fig. 5-1
Shut-down
voltage
typ.
55Vac
Steady-state value, see
Fig. 5-1
AC 100V
AC 120V
AC 230V
Input
current
typ.
0.91A
0.77A
0.47A
at 24V, 2.1A see
Fig. 5-3
Power
factor
*)
typ.
0.58
0.56
0.52
at 24V, 2.1A see
Fig. 5-1
Crest factor **)
typ.
3.05 3.26 3.91
at
24V,
2.1A
Start-up
delay
typ.
32ms 32ms 32ms
See
Fig. 5-2
Rise
time
typ.
33ms
33ms
48ms
0mF, 24V, 2.1A, see
Fig. 5-2
typ.
45ms
45ms
60ms
2mF, 24V, 2.1A, see
Fig. 5-2
Turn-on
overshoot
max.
400mV 400mV 400mV
See
Fig. 5-2
*)
The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit.
**) The crest factor is the mathematical ratio of the peak value to RMS value of the input current waveform.
Fig. 5-1
Input voltage range
Fig. 5-2
Turn-on behavior, definitions
Tur
n
-on
85V
Rated
input range
max.
500ms
V
IN
P
OUT
60V
300Vac
full
power
for
200ms
264V
S
hut
-down
Start-up
delay
Rise
Time
Ov
ershoot
- 5%
Output
Voltage
Intput
Voltage
Fig. 5-3
Input current vs. output load
Fig. 5-4
Power Factor vs. output load
2.1A
0.1
0.5
0.9
1.3
0
0.2
0.4
1.0A
Input Current, typ.
1.7
Output Current
0.6
0.8
a) 100Vac
b) 120Vac
c) 230Vac
b
c
a
2.1A
0.1
0.5
0.9
1.3
0.4
0.45
1.7
Output Current
0.5
0.55
0.6
0.65
Power Factor, typ.
a) 100Vac
b) 120Vac
c) 230Vac
b
c
a