background image

 

 

 

ML50.100, ML50.109 

 

MiniLine

 

 

24V, 2.1A, S

INGLE 

P

HASE 

I

NPUT

 

 

 

Mar. 2007 / Rev. 1.0  DS-ML50.100-EN 
All parameters are specified at 24V, 2.1A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 

www.pulspower.com   Phone +49 89 9278 0    Germany 

10/20 

 

16. EMC 

 

The CE mark indicates conformance with EMC guideline 89/336/EEC, 93/68/EEC and the low-voltage directive (LVD) 
73/23/EWG. A detailed EMC Report is available on request. 

 

 

EMC Immunity 

EN 61000-6-2, EN 61000-6-1   

Generic standards 

 

Electrostatic discharge  

EN 61000-4-2 

Contact discharge 
Air discharge 

8kV 
8kV 

Criterion A 
Criterion A 

  Electromagnetic RF field 

EN 61000-4-3 80MHz-1GHz 

10V/m 

Criterion 

 

Fast transients (Burst) 

EN 61000-4-4 

Input lines 
Output lines 

4kV 
2kV 

Criterion A 
Criterion A 

 

Surge voltage on input 

EN 61000-4-5 

Æ

 N 

N / L 

Æ

 PE 

2kV  
4kV 

Criterion A 
Criterion A 

 

Surge voltage on output 

EN 61000-4-5 

Æ

 - 

+ / - 

Æ

 PE 

500V 
500V 

Criterion A 
Criterion A 

  Conducted disturbance 

EN 61000-4-6 

0,15-80MHz 

10V 

Criterion A 

 

Mains voltage dips 

EN 61000-4-11 

0% of 100Vac

 

40% of 100Vac 
70% of 100Vac  
0% of 200Vac

 

40% of 200Vac 
70% of 200Vac 

0Vac, 20ms 
40Vac, 200ms 
70Vac, 500ms 
0Vac, 20ms 
80Vac, 200ms 
140Vac, 500ms 

Criterion A 
Criterion C 
Criterion A 
Criterion A 
Criterion A 
Criterion A 

  Voltage interruptions 

EN 61000-4-11 

 

0Vac, 5000ms 

Criterion C 

  Input voltage swells 

PULS internal standard 

 

300Vac, 500ms 

Criterion A 

 

Powerful transients 

VDE 0160 

over entire load 
range 

750V, 1.3ms 

Criterion A 

Criterions:

 

A:

  Power supply shows normal operation behavior within the defined limits.  

C:

  Temporary loss of function is possible. Power supply might shut-down and restarts by itself. No damages or hazards to the power 

supply will occur. 

 

 

EMC Emission

 

EN 61000-6-3, EN 61000-6-4 

Generic standards 

  Conducted emission  

EN 55011, EN 55022, FCC Part 15, CISPR 11, CISPR 22 

Class B, input lines 

   

EN 55022 

Class B, output lines  

  Radiated emission 

EN 55011, EN 55022 

Class B 

  Harmonic input current 

EN 61000-3-2  

Fulfilled 

  Voltage fluctuations, flicker EN 

61000-3-3 

 

Fulfilled 

 

This device complies with FCC Part 15 rules.  
Operation is subjected to the following two conditions: (1) this device may not cause harmful interference, and (2) this 
device must accept any interference received, including interference that may cause undesired operation. 

 

 

 

Switching frequency

 

variable, typ. 100kHz, (60-275kHz) 

Input voltage and output load dependent 

 

 

Summary of Contents for FAML50-100

Page 1: ...3W C 60 to 70 C Hold up time typ 35 190ms at 120 230Vac Dimensions 45x75x91mm WxHxD A compact size light weight simple mounting on the DIN rail and the quick connect spring clamp terminals are what ma...

Page 2: ...ENDED USE The power supply shall only be installed and put into operation by qualified personnel This power supply is designed for installation in an enclosure and is intended for the general use such...

Page 3: ...yp 3 05 3 26 3 91 at 24V 2 1A Start up delay typ 32ms 32ms 32ms See Fig 5 2 Rise time typ 33ms 33ms 48ms 0mF 24V 2 1A see Fig 5 2 typ 45ms 45ms 60ms 2mF 24V 2 1A see Fig 5 2 Turn on overshoot max 400m...

Page 4: ...ut Current Input 230Vac Output 24V 2 1A Ambient 40 C Upper curve Input current 20A DIV Middle curve Input voltage 1000V DIV Lower curve Output voltage 20V DIV Time scale 20ms DIV Input 230Vac Output 2...

Page 5: ...is also on during this time 9 DC OK OUTPUT This feature monitors the output voltage which is present on the output terminals The signal is a source output which can feed loads up to 30mA Loads can be...

Page 6: ...0W Short circuit current min 3 1A Load impedance 400mOhm see Fig 10 1 max 5A Load impedance 400mOhm see Fig 10 1 Fig 10 1 Output voltage vs output current 230Vac typ Output Voltage 0 0 1 2 4 8 12 28V...

Page 7: ...W 4 1W 4 4W 1 05A 24V typ 7 2W 6 6W 6 2W 2 1A 24V Fig 11 1 Efficiency vs output current at 24V Fig 11 2 Losses vs output current at 24V Efficiency 0 3 76 78 80 82 84 86 88 74 90 2 1A 0 9 1 2 1 8 Outpu...

Page 8: ...C 24V 1 05A min 96 000h 125 000h 152 000h 25 C 24V 2 1A MTBF SN 29500 IEC 61709 2 383 000h 2 456 000h 2 613 000h 40 C 24V 2 1A 3 977 000h 4 100 000h 4 362 000h 25 C 24V 2 1A MTBF MIL HDBK 217F 1 021...

Page 9: ...itive output Negative return output Dual pins per pole DC OK Open collector output Indicates an output voltage higher than 20Vdc 15 TERMINALS AND WIRING All terminals are easy to access when mounted o...

Page 10: ...70 of 200Vac 0Vac 20ms 40Vac 200ms 70Vac 500ms 0Vac 20ms 80Vac 200ms 140Vac 500ms Criterion A Criterion C Criterion A Criterion A Criterion A Criterion A Voltage interruptions EN 61000 4 11 0Vac 5000m...

Page 11: ...ltitudes from 2000m to 6000m Degree of pollution 2 EN 50178 IEC 62103 non conductive Fig 17 1 Output current vs ambient temp Fig 17 2 Output current vs altitude 24V 0 10 0 20 40 70 C 0 4 0 8 1 2 1 6 2...

Page 12: ...mains 0 40mA 264Vac 50Hz TN mains 20 DIELECTRIC STRENGTH Fig 20 1 Dielectric strength A B C Type test 60s 2500Vac 3000Vac 500Vac Factory test 5s 2500Vac 2500Vac 500Vac Field test 5s 2000Vac 2000Vac 5...

Page 13: ...n switched off Wiring must be in accordance with Class I Division 2 wiring methods of the National Electrical Code NFPA 70 and in accordance with other local or national codes Marine GL ABS GL Germani...

Page 14: ...te electrical and fire end product enclosure should be considered in the end use application Cooling Convection cooled no forced cooling required Do not cover ventilation grill e g cable conduits by m...

Page 15: ...Germany 15 20 26 ACCESSORY DIN Rail bracket for wall or panel mount A DIN rail bracket is included in each shipping box Fig 26 1 DIN Rail Bracket Fig 26 2 DIN Rail Bracket Dimensions Hole diameter 4...

Page 16: ...age is turned on before such an event the built in large sized output capacitors inside the power supply can deliver extra current Discharging this capacitor causes a voltage dip on the output The fol...

Page 17: ...adjusted output voltage draws current until it goes into current limitation This means no harm to this power supply as long as the ambient temperature stays below 50 C If a current sharing feature is...

Page 18: ...ower supply to different phases of the mains network 27 6 DAISY CHAINING OF OUTPUTS Daisy chaining jumping from one power supply output to the next is allowed as long as the maximum current through on...

Page 19: ...or two phase operation a A phase to phase connection is allowed as long as the supplying voltage is below 240V 10 b Use a fuse or a circuit breaker to protect the N input The N input is internally not...

Page 20: ...A1 Recommended output power Curve A2 Max allowed output power results approx in half the lifetime expectancy of A1 Fig 27 8 Mounting Orientation A Standard Orientation Power Supply OUTPUT INPUT Output...