![Puls DIMENSION CS5.243 Manual Download Page 6](http://html1.mh-extra.com/html/puls/dimension-cs5-243/dimension-cs5-243_manual_1624261006.webp)
CS5.243
C-Line
24V,
5A,
S
INGLE
P
HASE
I
NPUT
Nov. 2020 / Rev. 2.1 DS-CS5.243-EN
All parameters are specified at 24V, 5A, 120Vac, 60Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
6/26
Fig. 3-3
Input current vs. output load at 24V
Fig. 3-4
Power factor vs. output load
6A
1 1.5 2
3
4
0
0.5
1.0
1.5
2.0
2.5
3A
5
Output Current
2.5
3.5
4.5
5.5
Input Current, typ.
(a) 100Vac
(b) 120Vac
(a)
(b)
6A
1 1.5 2
3
4
0.35
0.40
5
Output Current
2.5
3.5
4.5
5.5
0.45
0.50
0.55
0.60
0.65
Power Factor, typ.
120Vac
100Vac
Fig. 3-5
Input voltage derating
0
30
40
50
70°C
1
2
3
4
5
6A
60
Ambient Temperature
A
A... at 85Vac, continuous
B... short term
B
Allowable Output Current at 85Vac