11
Problem solving
I2000ESD is designed and manufactured for a severe environment and tasks, but the user must note
that the machine components must be protected from knocks and blows. Filter, seals, attachments, and
connections are carefully adapted and selected with regard to the operator’s work environment.
Therefore, the operator and service personnel must treat the machine with care if it is to work correctly
for many years.
Problem
Cause
Procedure
Motor doesn’t start
No power
Connect the machine
Defective cable
Change
Defective switch
Change
Motor stops immediately on Wrong fuse
Connect to correct fuse
starting
Motor runs but there is
Hose not connected
Connect hose
No suction
Hose blocked
Clean hose
Motor runs but suction
Hole in the hose
Change hose
is poor
Filter blocked
Change filter
Sealing defective
Change current seal
Dust blows from motor
Filter defective or loose
Adjust or change
Abnormal noise
Order service