AC Line Fuses and Trips
The PS Series power amplifiers are provided with an 8 gauge 3 conductor
“pig tail” AC Line cord. This should be wired into a breaker box and feed
with a 2 pole 35A breaker.
Output Connector
Warning: The Flange output connector carries dangerously high RF
voltages that present shock and burn hazards. Never operate the PS power
amp without properly terminating the output connector in either an
adequately rated load or antenna.
Electrostatic Discharge (ESD)
A sudden discharge of electrostatic electricity can destroy static-sensitive devices or
micro-circuitry. Proper packaging and grounding techniques are necessary precautions to
prevent damage. Always take industry-standard precautions.
Grounding Methods
Guard against electrostatic damage at workstations by following these steps:
1. Cover workstations with approved anti-static material. Provide a wrist strap connected to
a work surface and properly grounded tools and equipment.
2. Use anti-static mats, heel straps, or air ionizers to give added protection.
3. Handle electrostatic-sensitive components, boards, and assemblies by the case or the PCB
edge.
4. Avoid contact with pins, leads, or circuitry.
5. Turn off power and input signals before inserting and removing connectors or test
equipment.
6. Keep the work area free of non-conductive materials such as ordinary plastic assembly
aids and Styrofoam.
7. Use field service tools, such as cutters, screwdrivers, and vacuums that are conductive.