Jumper Settings
45
Jumper Settings
The jumper settings for the 4-port, 8-port, and 16-port MPS1000 are identical and are shown in
Table 6-1, “K5 and K38 Jumper Settings,”
.
DIP Switch Settings
DIP switch usage depends on the port configuration of your MPS1000. The only DIP switches
used for the MPS1000 are SW1-1 and SW1-2. DIP switches SW1-3 and SW1-4 are not used
and must be left Open (OFF). The location of the DIP switches on the CPC358 are shown in
Figure 6-1, “K5, K38 Jumpers and SW1 Switch Location on the CPC358,” on page 44
.
4-Port Configuration
On the single CPC358, the DIP switch setting for SW1-1 must be in the Open (OFF) position
and the DIP switch setting for SW1-2 must be in the Closed (ON) position for the 4-port
MPS1000, as shown in
Table 6-2, “SW1 DIP Switch Settings for MPS1000 4-Port Version,”
.
8-Port Configuration
On the single CPC358, the DIP switch setting for SW1-1 must be in the Open (OFF) position
for the 8-port MPS1000 as shown in
Table 6-3, “SW1 DIP Switch Settings for MPS1000 8-Port
. DIP switches SW1-2 through SW1-4 are not used for this configuration and must be
left in the Open (OFF) position.
Table 6-1:
K5 and K38 Jumper Settings
Pins
Jumper
1
2
3
K5
Shunted
K38
Shunted
Table 6-2:
SW1 DIP Switch Settings for MPS1000 4-Port Version
SW1
Closed (ON)
Open (OFF)
Position 1
X
Position 2
X
Position 3
X
Position 4
X
Table 6-3:
SW1 DIP Switch Settings for MPS1000 8-Port Version
SW1
Closed (ON)
Open (OFF)
Position 1
X
Position 2
X
Position 3
X
Position 4
X
StockCheck.com
Summary of Contents for MPS1000
Page 4: ...4 S t o c k C h e c k c o m...
Page 8: ...Contents 8 S t o c k C h e c k c o m...
Page 10: ...Tables 10 S t o c k C h e c k c o m...
Page 12: ...Figures 12 S t o c k C h e c k c o m...
Page 16: ...Chapter 1 About This Guide 16 S t o c k C h e c k c o m...
Page 22: ...Chapter 2 Introduction 22 S t o c k C h e c k c o m...
Page 32: ...Chapter 3 Technical Information 32 S t o c k C h e c k c o m...
Page 50: ...50 S t o c k C h e c k c o m...