SIDE FOLD WALL MOUNT
3
4060
4064
6090
6094
9120
9124
ITEM
PART NUMBER
DESCRIPTION
QTY
QTY
QTY
QTY
QTY
QTY
40
5741
MTG KIT, AAG TO WM 63” (WIDE FRAME)
1
1
1
5742
MTG KIT, AAG TO WM 35” (NARROW FRAME)
1
1
1
41
4404
MTG KIT, 63X36 RECT BOARD TO AAG
1
1
1
4405
MTG KIT, 35X20 FAN TO AAG
1
1
1
Optional accessories: 9120-11-08 Crank Extension Arm
Locate, identify, and count all parts before starting the installation to ensure that all are correct and
correspond to the packing list/production drawings. If any parts are missing or damaged, DO NOT
SUBSTITUTE. Contact your authorized dealer or the manufacturer for assistance in obtaining the
correct part.
Also review production drawings to ensure that building conditions have not changed since the initial
field check. Verify overall height and width noted on drawings.
INSTALLATION PREPARATION
Before installing a wall mounted backstop unit, it
is imperative the structural integrity of the wall has
been evaluated and approved by an architect or
structural engineer for the loads that will be
imparted to the wall by the backstop.
The best wall construction for use with wall
mounted backstops is concrete masonry units
(CMU) or solid concrete panel. Further, through
bolting of the wood pads to the wall is the
recommended method of attachment. However,
when through bolting is not possible, the anchors
used must be of a type that will provide at least 5
times the load listed for the anchor point of the
unit. All anchors, including through bolts, must be
minimum ½” diameter and at least SAE Grade 5
equivalent material.
Mounting the wall mounted backstop to a wood
or metal stud structure is not recommended or
approved by the manufacturer unless the
structure has been reinforced as specifically
designed by an architect or structural engineer
for the desired wall mounted unit.
Please refer to the load charts on the following
page for information concerning the specific unit
being installed.