1. Make sure the CableMaster is turned OFF.
2. Insert the cable plug into the corresponding receiver on the main tes-
ter (RJ11 jack for voice cables, RJ45 jack for data cables, F-Connector
for video cables).
3. For data or voice cables, insert a Network or Voice wire mapping
remote into an RJ Jack wall port. For video cables, attach Coax wire
mapping remote(s) to the F-Connector coax wall receiver.
4. Press the O/ID button to turn the tester ON and enter ID Mode. Wire
mapping results display as follows
▪
A progression of “o’s” appear on the bottom of the display to
indicate ID Mode is active.
▪
If wire mapping remotes are found, the connector type il-
luminates and a numeric value (1 to 19) appears in the ID field
of the display screen showing the wire mapping remotes that
match the connected cable (see Figure 10).
▪
If wire mapping remotes are not found, “Open” displays in the
LCD screen.
▪
If multiple wire mapping remotes are found, the ID or fault is
displayed automatically in sequenceIf wire mapping remotes
are not found, “Open” displays in the LCD screen.
Figure 10.
Detected Coax Remote
1 2 3 4 5 6 7 8
Voice Data Video
Voltage!
Rev
Open
Short
ID
Split
Pass
Fail
Tone
X-over