SMOKE DETECTOR
We highly recommend the use of a smoke detector. It must be installed at least 15 feet (4,57 m) from the appliance
in order to prevent undue triggering of the detector when reloading.
ASH DRAWER
Your appliance is equipped with an ash drawer to collect ashes produced by the combustion of wood. This drawer
must not be left open during combustion as this will cause over firing and serious damage to the furnace.
The drawer must be cleaned regularly.
It is important that the door and the ash drawer be kept closed while the appliance is in use.
Maintain all gaskets in good condition: in case of deterioration, contact your dealer for
replacement.
ASH GRATE
You must replace the ash grate if it is damaged and a replacement may be obtained from your dealer.
3. APPLIANCE INSTALLATION
UNIT LOCATION
The furnace must be installed where outside air supply is sufficient for proper combustion. In airtight houses, it
might be necessary to install an outside air inlet (see details in: «3- INSTALLATION» D- COMBUSTION AIR).
The furnace must be positioned so that the connector is as short as possible in order to minimize the use of 90
o
elbows.
The owner must ensure a proper installation to allow a safe operation of the appliance.
6