Suggested Installation, Operation, Maintenance and Troubleshooting

 

 

Operating 

 

Troubleshooting

 

Pump will not run.

 

1.

 

Check for pressurized air at the inlet. 

2.

 

Check air inlet and filter for debris. 

3.

 

Connect a test lamp to the two wires which run to pump 

and ensure that the lamp cycles on and off. 

4.

 

Make sure that the air valve manual override (small red 

knob on front of valve) is switched to the “0” position. 

5.

 

Check pilot pressure vent at the top of the operator/ coil 
assembly to ensure that it is not clogged. 

6.

 

Check for a worn out air valve. If air continually blows out 
the exhaust in very large quantities, the air valve seals 
may be worn beyond their ability to function. In this case, 

the valve must be replaced. 

7.

 

NOTE: Before the valve is scrapped, it is possible that it 

may be saved by completely disassembling the valve, 
cleaning all components and relubricating the valve. 

Pump runs but little or no fluid comes out.

 

1.

 

Check that the discharge isolation valve is not closed. 

2.

 

Check that the electronic signal is slow enough that the 

pump is able to complete each physical stroke before it 
is signaled to change direction. The time required to 
complete the stroke is determined by a variety of factors 

which include fluid viscosity and head pressure. 

3.

 

Check for pump cavitation; slow pump speed down to 

match the thickness of the material being pumped. 

4.

 

Check for sticking ball check valves. If the material  

being pumped is not compatible with the pump 
elastomers, swelling may occur. Replace ball check 
valves and o-ring with the proper elastomers. 

5.

 

Check to make sure that all suction connections are 
airtight, and that the clamp bands are properly tightened. 

Pump air passages blocked with ice.

 

1.

 

Check for excessive moisture in compressed air line.  
As the air expands out the exhaust during the operation of  

the pump, water vapor entrapped   in the compressed air  
can freeze and block the air passageways in the pump.  
If this occurs, it may be necessary to install a coalescing  

filter, an air dryer, or a hot air generator for the compressed air. 

Air bubbles in pump discharge.

 

1.

 

Check for ruptured diaphragm. 

2.

 

Check tightness of clamp bands, and the integrity of the  

o-rings, especially at intake manifold. 

Product comes out of the air exhaust.

 

1.

 

Check for diaphragm rupture. 

2.

 

Check tightness of piston plates to shaft. 

Pump rattles.

 

1.

 

See E10 Troubleshooting Guide. 

2.

 

Create false discharge head or suction lift. 

Solenoid buzzes or solenoid burnout.

 

1.

 

Incorrect voltage, faulty or dirty solenoid. 

Solenoid valve fails to shift electrically but shifts  
with manual override.

 

1.

 

Incorrect voltage, defective coil or wiring. 

Solenoid valve fails to shift electrically or  
with manual over- ride.

 

1.

 

Inadequate air supply, contamination, inadequate or improper lubrication, 

mechanical binding in the valve. 

Valve shifts but fails to return.

 

1. 

Broken spring, mechanical binding. 

Excessive leaking from air valve vent.

 

1.

 

Worn seals in air valve. 

 
 
 

 

 

 

 

Summary of Contents for WILDEN A200B Advanced Plastic

Page 1: ...EOM ENGINEERING OPERATION MAINTENANCE A200 Accu Flo Bolted Plastic Pump WIL 11060 E 03 Where InnovationFlows...

Page 2: ...7 A200P Advanced Plastic 7 A200B Advanced Plastic 7 Section 5 Performance 8 A200P Rubber Fitted 8 A200P PTFE Fitted 8 Suction Lift Curves 9 Section 6 Suggested Installation Operation 10 Maintenance a...

Page 3: ...ifornia LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are regist...

Page 4: ...pply for PFA pumps CAUTION Do not exceed 8 6 bar 125 psig air supply on polypropylene and PVDF pumps CAUTION Advanced series plastic pumps are made with plastic that is not UV stabilized Direct sunlig...

Page 5: ...Brown TV PTFE ENCAP FKM WF WIL FLEX Santoprene SPECIALTY CODES 0150 Accu Flo 24V DC coil 0151 Accu Flo 24V AC 12V DC coil 0167 Accu Flo 24V AC 12V DC coil Wil Gard II 110V 0180 Accu Flo 24V AC 12V DC...

Page 6: ...he pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The move...

Page 7: ...4 3 R 353 13 9 S 310 12 2 T 124 4 9 U 157 6 2 V 10 0 4 DIN mm ANSI inch W 85 DIA 3 1 DIA X 115 DIA 4 3 DIA Y 14 DIA 0 6 DIA A200B Advanced Plastic DIMENSIONS ITEM METRIC mm STANDARD inch A 457 18 0 B...

Page 8: ...umps should be specified so that daily operation parameters will fall in the center of the pump performance curve A200P PTFE FITTED Height 434 mm 17 1 Width 457 mm 18 0 Depth 257 mm 10 1 Est ShipWeigh...

Page 9: ...LASTIC SUCTION LIFT CAPABILITY These curves demonstrate the flow created when the stroke rate is modified under static air and fluid pressure condition This curve can be applied to different pressure...

Page 10: ...he use of an air filter before the pump will insure that the majority of any pipeline contaminants will be eliminated Solenoid Operation When operation is controlled by a solenoid valve in the air lin...

Page 11: ...nce power is regained Air Operated Pumps To stop the pump from operating in an emergency situation simply close the shut off valve user supplied installed in the air supply line A properly functioning...

Page 12: ...required a record should be made of all necessary repairs and replacements Over a period of time such records can become a valuable tool for predicting and preventing future maintenance problems and u...

Page 13: ...ng pumped 4 Check for sticking ball check valves If the material being pumped is not compatible with the pump elastomers swelling may occur Replace ball check valves and o ring with the proper elastom...

Page 14: ...WIL 11060 E 03 Wilden 14 EXPLODED VIEW AND PARTS LISTING A200P ADVANCED PLASTIC Rubber TPE Fitted EXPLODED VIEW Section 7...

Page 15: ...20 17 Shaft Straight P2 1 02 3810 03 02 3810 03 02 3810 03 18 Washer Disc Spring 413 X 906 2 02 6802 08 02 6802 08 02 6802 08 19 Piston Inner P2 2 02 3701 01 02 3701 01 02 3701 01 20 Diaphragm Primary...

Page 16: ...WIL 11060 E 03 Wilden 16 A200P ADVANCED PLASTIC PTFE Fitted EXPLODED VIEW EXPLODED VIEW AND PARTS LISTING...

Page 17: ...6802 08 02 6802 08 19 Piston Inner P2 2 02 3751 01 02 3751 01 02 3751 01 20 Diaphragm Back Up Neoprene 2 02 1060 51 02 1060 51 02 1060 51 21 Diaphragm Primary 2 02 1010 55 02 1010 55 02 1010 55 22 Pis...

Page 18: ...able upon request Please consult your local distributor Solenoid Operated Valve Assembly Options Consists of Valve Body Coil and Connector Pump Models Designating Specialty Code Part Number Descriptio...

Page 19: ...WIL 11060 E 03 Wilden Notes...

Page 20: ...Terrace CA 92313 5651 USA P 1 909 422 1730 F 1 909 783 3440 psgdover com Where Innovation Flows PSG reserves the right to modifythe information and illustrations contained in this document without pr...

Reviews: