PERFORMANCE
A200P
RUBBER-FITTED
Height ............................ 434 mm (17.1")
Width ............................. 457 mm (18.0")
Depth ............................. 257 mm (10.1")
Est. Ship Weight .....................................
Polypropylene 14 kg (31 lbs)
PVDF 19 kg (41 lbs)
Air Inlet.................................... 6 mm (1/4")
Inlet ........................................ 25 mm (1")
Outlet ....................................... 25 mm (1")
Suction Lift ................... 4.8 m Dry (15.9')
9.3 m Wet (30.6')
Disp. Per Stroke
1
............. .
0.34 l (0.09 gal.)
Max. Flow Rate ............ 170 lpm (45 gpm)
Max. Size Solids ................. 4.8 mm (3/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2 bar (30 psig) head pressure.
Example:
To pump 75.7 lpm (20 gpm)
against a discharge pressure head of
3.4 bar (50 psig) requires 5.5 bar (80 psig)
and 34 Nm
3
/h (20 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump performance curve.
A200P
PTFE-FITTED
Height ............................ 434 mm (17.1")
Width ............................. 457 mm (18.0")
Depth ............................. 257 mm (10.1")
Est. Ship Weight .....................................
Polypropylene 14 kg (31 lbs)
PVDF 19 kg (41 lbs)
Air Inlet.................................... 6 mm (1/4")
Inlet ........................................ 25 mm (1")
Outlet ....................................... 25 mm (1")
Suction Lift ................... 4.8 m Dry (15.9')
9.3 m Wet (30.6')
Disp. Per Stroke
1
............. .
0.34 l (0.09 gal.)
Max. Flow Rate ............ 170 lpm (45 gpm)
Max. Size Solids ................. 4.8 mm (3/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure against
a 2 bar (30 psig) head pressure.
Example:
To pump 30.3 lpm (8 gpm)
against a discharge pressure head of
4.1 bar (60 psig) requires 5.5 bar (80 psig)
and 20.4 Nm
3
/h (12 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Section 5
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump performance curve.