Programming Options
45
PowerWedge
®
10
Table 7
CODE PARAMETER
I.D.
#
TYPE
ACCEPTABLE
INPUT
PREDEFINED
DEFAULT (C8)
Enter 1 for On and 0 for Off.
Data type
C0
Value
50 = ASCII
51 = PC scan codes
50
Baud rate
C1
Value
00 = 300
01 = 600
02 = 1200
03 = 2400
04 = 4800
05 = 9600
06 = 19200
07 = 38400
08 = 57600
05
Data bits*
C2
Value
07 = 7 Bits
08 = 8 Bits
08
Parity*
C3
Value
00 = None
01 = Mark
02 = Space
03 = Odd
04 = Even
00
Stop bits*
C4
Value
01 = 1 Bit
02 = 2 Bits
01
Xon/Xoff handshaking
C5
On/
Off
On
or
Off
Off
Predefined serial defaults
C8
Protocol
CA
Value
00 = EOR only
01 = ACK/NAK
00
Timeout
CD
Value
00–99
†
00 = 2.55 seconds
01
*The PowerWedge 10 will not operate with a combination of 7 data bits, no parity, and 1 stop bit
†
10-millisecond increments; the default setting (01) means 10 milliseconds