background image

1

 

Lithium (sealed non-replaceable) 
Battery-Operated Photoelectric Smoke Alarm 
with wireless RF Interlink and HUSH Control 

You do NOT need a home Wi-Fi system to use 
these units. Multiple wireless units create their 
own independent wireless 
RF interlink network.

Smoke Alarm with RF Interlink User Guide

Tested & Complies to
Australian Standards
    AS3786:2014 

AS 3786:2014

Lic:SMK1377

SAI Global

Model 6000DCW

Part Number: LIF6000DCW

Summary of Contents for LIFESAVER 6000DCW

Page 1: ...Control You do NOT need a home Wi Fi system to use these units Multiple wireless units create their own independent wireless RF interlink network Smoke Alarm with RF Interlink User Guide Tested Compli...

Page 2: ...module are powered by a non replaceable long life sealed lithium battery system which will last up to 10 years after power up under normal operation NOTE A NETWORK IS LIMITED TO 24 ALARMS Teach child...

Page 3: ...ding Another Device to an Existing RF Interlink Network 10 6 3 Resetting a Device s RF Interlink Settings 11 7 Wireless FAQs 12 8 Installation Instructions 13 9 Operating Testing and Alarm Characteris...

Page 4: ...e exit If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in If the escape route requires you to go through smoke sta...

Page 5: ...y Supervised wireless network Radio Frequency 918MHz Wireless interconnectable to other compatible alarms RF Interlink Range 100m line of sight 30m indoors Distances will vary depending on walls and o...

Page 6: ...smoke and heat Locate at least one alarm on every floor level Locate an alarm in every room where a smoker sleeps Locate an alarm in every room where electrical appliances are operated i e portable h...

Page 7: ...e alarm may decrease operational effectiveness Typical Multiple Floor Installation Location of smoke alarm Apex Of Sloping Ceiling Ceiling Wall Junction Single Floor Smoke alarms for minimum protectio...

Page 8: ...particles may cause smoke alarm to false alarm or fail to alarm Use Lifesaver Heat Alarm in this location to avoid false alarms In dusty areas dust particles may cause nuisance alarm or failure to ala...

Page 9: ...s network master unit that is the key communicator with the other wireless units This assignment remains until the Coordinator is reset section 6 3 IMPORTANT The Coordinator unit should be installed i...

Page 10: ...flashes three times every 2 seconds to indicate it is configured as an RFD in the network Join Mode will timeout in 15 minutes Step 3 After new unit s have joined press button twice on any unit in th...

Page 11: ...or family s place User Input Detector Response Timeout Step 1 Press button twice quickly to enter Join Mode Network enters Join Mode Its Red LED will flash either Twice every 2 seconds as Coordinator...

Page 12: ...ew unit and wait for it to join Push any button twice to close network See section 6 2 5 Can the joining process be reset restarted Yes Push button twice to open network Push hold button for approx 4...

Page 13: ...icated on the alarm cover until the alarm snaps into place and beeps once The smoke alarm will only install onto the mounting bracket in one direction Use the alignment indicator The alarm is now acti...

Page 14: ...resist tab snap into place locking the alarm on the mounting bracket Using the tamper resist feature will help deter children and others from removing the alarm from the bracket Figure 6 Figure 7 Tamp...

Page 15: ...other alarms activate Always stand about 1m away from the unit during testing to avoid ear discomfort Pushing the button will sound the alarm if the electronic circuitry horn and battery are working...

Page 16: ...ult Flashes 1 sec ON 1 sec OFF for 15mins Then flash once every 30secs Chirp every 30 seconds Perform a General Reset mode and re join network Maintenance Feature 5 quick flashes before T3 pattern Non...

Page 17: ...ing Using the fan on a range hood which vents to the outside non recirculating type will also help prevent nuisance alarms from occurring by removing these combustible products from the kitchen Smoke...

Page 18: ...may reduce battery life WARNING DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON Do not try to repair the smoke alarm yourself No serviceable parts included Low battery This alarm has a low battery mo...

Page 19: ...to discharge alarm as instructed prior to disposal may cause lithium battery related hazard eg fire After the tab is broken please insert screw driver into slot and slide switch towards the top of th...

Page 20: ...ms can be wirelessly controlled with a Smoke Alarm Remote Control Model 6000THL The Remote Control can TEST LOCATE and HUSH the smoke alarms Smoke Alarms Models 6000 and 6000RL require a wireless base...

Page 21: ...ection 8 Clean the smoke alarm with compressed air or a vacuum cleaner by blowing or vacuuming through the vent openings around the rear rim of the smoke alarm The outside shell of the smoke alarm can...

Page 22: ...e a fire drill at least every six months including fire drills at night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice...

Page 23: ...rms must be tested regularly to ensure the batteries and the alarm circuits are in good operating condition Smoke alarms cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarm...

Page 24: ...each of this or Any other warranty express or implied loss or damage caused by failure to abide by the instructions supplied in the leaflets 4 To the extent permitted by law PSA Products Pty Ltd makes...

Page 25: ...uct for warranty to ensure fast and effective service Otherwise please retain this warranty section and complete the details below When you claim Warranty for the product please present this section t...

Page 26: ...uality Product By PSA Products Pty Ltd 17 Millicent Street Burwood Victoria 3125 Australia Ph 1300 PSA PRODUCTS 1300 772 776 Email enquiry psaproducts com au Webite www psaproducts com au Tested Compl...

Page 27: ...O alarm with rechargeable lithium battery LIFCO240 Battery powered CO alarm LIFCO9D Heat Alarm Mains powered heat alarm with 9V battery LIFHA240 Ancillaries Wireless remote smoke alarm controller LIF6...

Reviews: