8. Installation Instructions
After selecting the proper smoke alarm location as described in Section 4, attach the mounting
bracket to the ceiling as shown in Figure 4. Use the screws and cavity fixings provided to secure
the mounting bracket (use 5mm drill bit for cavity fixings.)
Install the alarm on the mounting bracket (Figure 5) and gently rotate the alarm clockwise (as
indicated on the alarm cover) until the alarm snaps into place and beeps once. The smoke alarm
will only install onto the mounting bracket in one direction. Use the alignment indicator.
The alarm is now activated!
After installation/activation, test your alarm as described Section 9 (Operation & Testing).
IMPORTANT:
Removing the smoke alarm from its mounting bracket will de-activate the unit.
Figure 4
Figure 5
When mounting
in a hallway, the
“A” line should
be perpendicular
to the hallway.
Align the arrow
and alignment
mark on the side
of alarm. Turn
clockwise to
mount.
Install
A
A
Figure 4