6. Activation and RF Interlink Network
This model is capable of interlinking with other PSA 6000DCW alarms in domestic residential
applications. When one RF interlink unit sounds an alarm, all other compatible RF units in the RF
interlink network will alarm. Follow the steps in section 6.1 to interlink up to 24 units in your interlink
network. If you have problems during setup, see section 6.3 to start over.
NOTE : Wireless units will emit a series of LED flashes and beeps as the unit(s) search for an RF
interlink network. If you are intending to use wireless units without the wireless function, ignore these
notifications, and the wireless function will eventually turn off. You can turn the wireless function on
again at a later date if desired. See Section 6.2.
NOTE : The battery is switched ON when the smoke alarm is installed onto its mounting plate; and
turned OFF when the device is removed from its bracket. See Permanently Disable Alarm / Discharge
Battery section13.
Definitions of key terminology:
Coordinator:
The wireless network master unit that is the key communicator with the other wireless
units. This assignment remains until the Coordinator is reset (section 6.3).
IMPORTANT:
The Coordinator unit should be installed in a central location of the residence.
RF Device (RFD):
The other wireless units that connect to the Coordinator.
General Reset mode:
Resets a unit to when it was powered on for the first time after being removed from the
package.
6.1 Setting Up an RF Interlink Network
For easy first time setup, we recommend unpacking all the units together on a table. If you prefer
to install the alarms on the ceiling before setting up the wireless network, then first attach all the
mounting brackets to the ceiling. Next, choose the most centrally located unit and begin with Step 2
below.
User Input
Detector Response
Timeout
Step 1
Unpack all units
Step 2
Power up the first unit by rotat-
ing the unit onto its mounting
bracket.
Unit powers up - Red LED one
second on one second off, and
one chirp
Step 3
2 Button Presses on First Unit
2 soft beeps and two quick Red LED
flashes every 2 seconds to indicate
unit is configured as a Network
Coordinator and a sonar ping sound
indicates that Join Mode is Open
Join Mode will timeout in 15 minutes