12. Maintenance and Repair
Maintenance
Under the conditions of use as per specification as lined out in the data sheet, the PS-AMS
actuators are free of maintenance. All gears are lubricated for their service life and do not
require to be re-lubricated.
Cleaning
Clean the actuators with a dry soft cloth and do not use any cleaning agent. Do not use any
coarse or abrasive materials.
13. Safety on Transportation
For transportation and storage all cable glands and connection flanges have to be closed to prevent ingress of
moisture and dirt. A suitable method of packaging is required for transporting to avoid damage of coating and any
external parts of the actuator.
14. Accessories
Acc
essories/ O
ptions
Add'l Position Switches
2WE
Potential-free additional position switches with silver contacts (0.1
A - 5 A switching current)
Add'l Position Switches
Gold
2WE
Gold
Potential-free additional position switches with gold contacts (0.1
mA - 100 mA switching current)
Integrated process
controller
Enables the autonomous control of a process so that an external
controller is not required.
Fail-Safe*
PSCP
Emergency power supply based on supercapacitors, safety
position OPEN, CLOSED or free defined position
Fieldbus Interface*
Digital transmission of nominal and actual value per mill or
percent, report of monitoring and diagnostic data using Profibus
DP (PSPDP) or CANOpen (PSCA) interfaces, additional interfaces
available on request
Local Control*
PSC.2
Illuminated display to show the actuator status and lockable
selector to switch between modes: automatic, manual
process ON/OFF, STOP and parameter menu. Control
buttons for manual movement, menu operation and
adjustment of parameters, display of diagnostic information
Remote Local Control
mounting separately from the actuator (incl. 10 m connection
cable)
Data Cable
PSCS-
USB
USB data cable enables the communication between the actuator
and a PC by using the software PSCS
Fault Indication Relay*
FIR
potential-free opening contact provides a freely definable
collective fault signal
Fail-Safe Port*
FSP
Signal port to drive to a "safety position", selectable fail-safe
position, standard 24 V
Corrosion Protection
K2
Increased corrosion protection incl. heating resistor
IP68
Increased enclosure IP68
Heating Resistor
HR
Heating resistor to prevent condensation
Terminal Box*
Plug and socket in an IP68 box
*not retrofittable