Prozone ProC232J Installation Manual Download Page 4

R

O

B/W1

Y1

G

DSBK

HV

A

C E

QUIPMENT

W2/E

Y2

R

C

W1/OB

W2/E

Y

G

ZONE1 TS

TA

T

R

C

W1/OB

W2/E

Y

G

ZONE1 TS

TA

T

Zone 2 or 3 Thermostat

Heat/Cool

24VAC

R
C

W1/OB

W2/E

Y1
Y2

G

Zoning Panel

Wiring Zone Thermostats

Wiring HVAC Equipment

Heat/Cool Thermostats

Gas/Electric System, Two-Stage Heat

Heat Pump Thermostats with Auxiliary Heating

Gas/electric systems using Heat/Cool thermostats.  Wiring for 
these thermostats is shown below.

Heat/Cool thermostats can be used in all zones. A heat pump 
thermostat can be used in Zone1 with heat pump equipment to 
control emergency heating.  The type of thermostat can be 
selected using the PDMi3.

Gas/Electric systems using a single 24VAC transformer are 
wired as shown below.  RC and RH are jumpered on the panel.

When using a heat pump thermostat, on the thermostat select 
O operation of the reversing valve.  If both an O and B terminal 
are  provided on the thermostat, wire the thermostat O terminal 
to the W1/OB terminal at the Zone1 thermostat terminals.

5.

6.

A heat pump thermostat should be used in Zone1 when heat 
pump equipment is selected.  Wiring of a heat pump zone 
thermostat is shown below.

Thermostat

R

C

OB

W2/E

Y1

G

Zoning Panel

Terminal Function

24VAC

24VAC Common

Reversing valve.

Auxiliary Heating/Emergency Heating

Stage1 Compressor

Indoor Fan 

R

C

W1/OB

W2/E

Y

G

5-conductor

18 gage

Thermostat Wire

RC

HVAC SYSTEM

Line

24VAC

Gas Valve1

W1

R

W2

Y1

G

Gas Valve2

Compressor1

Indoor Fan

Zoning Panel

R

B/W1

W2/E 

Y1

G

Equipment

Terminal Function

24VAC for Thermostat and Terminals

Gas Valve, Stage1

Gas Valve, Stage2

Compressor Stage1

Indoor Fan

R

W1

W2

Y1

G

R

C

W1

Y1

G

ZONE2 TST

A

T

R
C

W

Y

G

R

C

W1

Y1

G

Zoning Panel 

Thermostat

R

C

Y or Y1

G

Zoning Panel

R

C

24VAC 

24VAC Common

Cooling, Stage1

Indoor Fan

Y

G

Terminal Function

W1

Stage1 Heating

Zoning Panel

Zone 1 Thermostat

Heat/Cool

24VAC

Thermostat

R

C

Y or Y1

G

Zoning Panel

R

C

24VAC 

24VAC Common

Cooling, Stage1

Indoor Fan

Y

G

Terminal Function

W1/OB

Stage1 Heating

W1/OB 

Inside

Day

Th

MODE

MENU

FAN

SYSTEM

Schedule

Auto

Heat

Heat

Set To

AM

Inside

Day

Th

MODE

MENU

FAN

SYSTEM

Schedule

Auto

Heat

Heat

Set To

AM

Inside

Day

Th

MODE

MENU

FAN

SYSTEM

Schedule

Auto

Heat

Heat

Set To

AM

4

Summary of Contents for ProC232J

Page 1: ...umps Selected using the PDMi3 plug in programming display module See table below See table below See table below HVAC PANEL ZONE DAMPERS 1 1 2 2 3 Fresh Air 3 THERMOSTATS Quick View Zoning Panel ProZo...

Page 2: ...the plenum or freezing the indoor coil Color coded terminals for heat cool or heat pump thermostat Thermostat type selected using the PDMi3 Use 24VAC powered or battery powered thermostats VAC termina...

Page 3: ...stall the 24VAC transformer according to local electrical codes and connect the 24VAC output to the terminals on the panel using 2 conductor 18 gage thermostat wire as shown below 1 2 3 4 HVAC PANEL Z...

Page 4: ...heat pump thermostat should be used in Zone1 when heat pump equipment is selected Wiring of a heat pump zone thermostat is shown below Thermostat R C OB W2 E Y1 G Zoning Panel Terminal Function 24VAC...

Page 5: ...the red and white thermostat wires to the thermistor wires no polarity using the wirenuts 3 Push the wirenuts and wire into the cover and secure the cover with the screw 1 Connect the red and white th...

Page 6: ...respond to the Zone1 thermostat When the occupant leaves the home they can set the switch to Vacant and only set the Zone1 thermostat Installing the Duct Pressure Sensor Drill a 3 8 inch diameter hol...

Page 7: ...es or navigate Press the CANCEL to cancel settings and return to the main menu The panel is ready to operate and control the equipment selected The PDMi3 can be used to customize the panel clone it fr...

Page 8: ...s Yes to set the number of stages of heating and cooling the fan operation the supply air temperature limits outdoor changeover temperature for dual fuel heat pumps and number of zones being used Pres...

Page 9: ...T Aux Heating 1 Stages U D NEXT Fan Mode Gas N NEXT Htg Temp Lmt 160 U D NEXT Htg Temp Lmt 160 U D NEXT Clg Temp Lmt 45 U D NEXT Clg Temp Lmt 45 U D NEXT Total Zones 3 Used U D NEXT Total Zones 3 Used...

Page 10: ...heat cool thermostat for that zone Press No to see other thermostats that can be used in that zone Press Up or Down to change the number of auxiliary heating stages Press NEXT to continue If a heat pu...

Page 11: ...Y N Bypass Ext Baro Y N Bypass ZoneDmprs Y N Zone1 Htg 50 BP Pos U D NEXT Zone1 Clg 50 BP Pos U D NEXT Zone2 Htg 50 BP Pos U D NEXT Zone2 Clg 50 BP Pos U D NEXT Zone3 Htg 50 BP Pos U D NEXT Zone3 Clg...

Page 12: ...N Fresh Air Off Y On N Off If the contractor has calculated the CFM for fresh air and sized the damper to operate for a number of minutes each hour the minutes can be directly entered The PDMi3 allows...

Page 13: ...Down to set the weighted zones when low speed fan is activated In the example if the weighted demand is less than 2 0 DSBK is activated Press Next to continue to next menu selection Press Yes to selec...

Page 14: ...ooling stage Press Yes to start a test of the heating system to insure discharge temperature is correct Press Next to start a test stage2 heating to insure discharge temperature is correct or return t...

Page 15: ...select the letter or number Press NEXT to go to the next letter in the name Press SAVE to save the clone name Monitor HVAC Performance Y N LAT 122 Prs 0 55 BP Pos 35 NEXT Press Yes to display the leav...

Page 16: ...una Hills CA 92653 949 916 0945 Fax 949 458 8502 www ProZone US com Limited 5 Year Warranty The 5 year warranty is limited to the repair or replacement of defective product due to parts failure or def...

Reviews: