Prozone ProC232J Installation Manual Download Page 15

15

Restore Defaults
             Y/N

Press Yes to restore the panel to the 
factory settings.  Press No to continue.

Save Options Now
             Y/N

Save Selections
As Clone     Y/N

Description For
Clone 1     NEXT

A
   U/D/NEXT/SAVE

Press Yes to save the options and 
settings selected.  Press No to return to 
the main menu.

Press Yes to save the options as a 
new clone to be used later.  Press 
No to return to the main menu.

Press NEXT to enter the name for 
Clone 1.

Press Up or Down to select the letter 
or number.  Press NEXT to go to the 
next letter in the name.  Press SAVE 
to save the clone name.

Monitor HVAC
Performance  Y/N

LAT 122 Prs 0.55
BP Pos 35%  NEXT

Press Yes to display the leaving air 
temperature, duct pressure and the 
position of the non-calling zone 
dampers when used for bypass.  
Press No to continue.

Displays the leaving air 
temperature, duct pressure and 
the position of the non-calling 
zone dampers when used for 
bypass.  The data is automatically 
updated every 5 seconds.  Press 
Next to return to the main menu.

Save Clone
Description  Y/N

Press Yes to save the clone data 
and the name.  Press No to return to 
the main menu.

Summary of Contents for ProC232J

Page 1: ...umps Selected using the PDMi3 plug in programming display module See table below See table below See table below HVAC PANEL ZONE DAMPERS 1 1 2 2 3 Fresh Air 3 THERMOSTATS Quick View Zoning Panel ProZo...

Page 2: ...the plenum or freezing the indoor coil Color coded terminals for heat cool or heat pump thermostat Thermostat type selected using the PDMi3 Use 24VAC powered or battery powered thermostats VAC termina...

Page 3: ...stall the 24VAC transformer according to local electrical codes and connect the 24VAC output to the terminals on the panel using 2 conductor 18 gage thermostat wire as shown below 1 2 3 4 HVAC PANEL Z...

Page 4: ...heat pump thermostat should be used in Zone1 when heat pump equipment is selected Wiring of a heat pump zone thermostat is shown below Thermostat R C OB W2 E Y1 G Zoning Panel Terminal Function 24VAC...

Page 5: ...the red and white thermostat wires to the thermistor wires no polarity using the wirenuts 3 Push the wirenuts and wire into the cover and secure the cover with the screw 1 Connect the red and white th...

Page 6: ...respond to the Zone1 thermostat When the occupant leaves the home they can set the switch to Vacant and only set the Zone1 thermostat Installing the Duct Pressure Sensor Drill a 3 8 inch diameter hol...

Page 7: ...es or navigate Press the CANCEL to cancel settings and return to the main menu The panel is ready to operate and control the equipment selected The PDMi3 can be used to customize the panel clone it fr...

Page 8: ...s Yes to set the number of stages of heating and cooling the fan operation the supply air temperature limits outdoor changeover temperature for dual fuel heat pumps and number of zones being used Pres...

Page 9: ...T Aux Heating 1 Stages U D NEXT Fan Mode Gas N NEXT Htg Temp Lmt 160 U D NEXT Htg Temp Lmt 160 U D NEXT Clg Temp Lmt 45 U D NEXT Clg Temp Lmt 45 U D NEXT Total Zones 3 Used U D NEXT Total Zones 3 Used...

Page 10: ...heat cool thermostat for that zone Press No to see other thermostats that can be used in that zone Press Up or Down to change the number of auxiliary heating stages Press NEXT to continue If a heat pu...

Page 11: ...Y N Bypass Ext Baro Y N Bypass ZoneDmprs Y N Zone1 Htg 50 BP Pos U D NEXT Zone1 Clg 50 BP Pos U D NEXT Zone2 Htg 50 BP Pos U D NEXT Zone2 Clg 50 BP Pos U D NEXT Zone3 Htg 50 BP Pos U D NEXT Zone3 Clg...

Page 12: ...N Fresh Air Off Y On N Off If the contractor has calculated the CFM for fresh air and sized the damper to operate for a number of minutes each hour the minutes can be directly entered The PDMi3 allows...

Page 13: ...Down to set the weighted zones when low speed fan is activated In the example if the weighted demand is less than 2 0 DSBK is activated Press Next to continue to next menu selection Press Yes to selec...

Page 14: ...ooling stage Press Yes to start a test of the heating system to insure discharge temperature is correct Press Next to start a test stage2 heating to insure discharge temperature is correct or return t...

Page 15: ...select the letter or number Press NEXT to go to the next letter in the name Press SAVE to save the clone name Monitor HVAC Performance Y N LAT 122 Prs 0 55 BP Pos 35 NEXT Press Yes to display the leav...

Page 16: ...una Hills CA 92653 949 916 0945 Fax 949 458 8502 www ProZone US com Limited 5 Year Warranty The 5 year warranty is limited to the repair or replacement of defective product due to parts failure or def...

Reviews: