Technical data  

Device 

weight 

maximum 

Patient 

weight 

maximum 

Training 

weight 

maximum 

Isometric 

load  

maximum

 

Adjustable size 

Depth x width x 

height in cm

 

Movement 

dimension 

Depth x width x 

height in cm

 

tergumed 

®

600 Lateral Flexion 

370 kg 

180 kg 

80 kg 

3.000 N 

126 x 92 x 163 

126 x 115 x 163 

tergumed 

®

600 Rotation 

400 kg 

180 kg 

160 kg 

2.000 N 

128 x 148 x 163  

130 x 148 x 171 

 

Ambient conditions Operation 

 

Temperature 

+5° to +45° Celsius 

Humidity 

<65% 

 

 

Transport and storage 

 

Temperature 

-10° to +45° Celsius 

Humidity 

<65% 

 

 

Requirements 

 

Medical Device Directive  

93/ 42/EEC 

Product life 

7 years as medical device 

Stationary training equipment 

EN ISO 20957-1, ISO 20957-2 

Use class according to ISO 20957-1 

S/I 

Risk classification 

 

93/ 42/ EEC 

Class IIa 

 

 

 

 

Summary of Contents for tergumed 600 Lateral Flexion

Page 1: ...tergumed 600 Lateral Flexion Rotation User Manual ...

Page 2: ...2 In this user manual you will find information on the following products tergumed 600 Lateral Flexion tergumed 600 Rotation ...

Page 3: ...cess is based on the holistic understanding of the needs of our clients and their customers Maximum therapeutic success and personal quality of life improvement for all people are our incentive in the changing healthcare system of the future For the health of your patients and the long lasting use of our products please read this manual carefully with all important information for a safe and corre...

Page 4: ... Patient target group 11 3 7 Clinical benefit 11 3 8 Responsible operation 11 3 9 Safety regulations 12 3 10 Combination with other products 12 3 11 Side effects and residual risks 12 3 12 Incident reporting 12 4 Storage transport and installation 13 5 Commissioning 15 6 Training tips 16 7 Device descriptions 18 7 3 tergumed 600 Lateral Flexion 18 Intended use 18 Indications 18 Settings 19 7 4 ter...

Page 5: ...5 8 Maintenance cleaning servicing disposal 26 9 Service 28 10 Accessories 29 11 Technical data 31 12 Warranty 32 ...

Page 6: ...t 2 1 General symbolism Symbolism Meaning Adjustment range Indicates the range in which each setting can be made The setting ranges are approximate values that may vary depending on the setting element Rotational adjustment range Top view If the adjustment is made in the horizontal direction the 90 of the coordinate system always point in the direction of the backrest of the training device Rotati...

Page 7: ...nt 2 2 Safety instructions legend The safety instructions presented in the operating instructions are categorized as follows Safety notice Meaning WARNING WARNING Indicates a potentially dangerous situation If the situation is not avoided death or serious injury may result CAUTION CAUTION Indicates a potentially dangerous situation If the situation is not avoided an injury may result ATTENTION ATT...

Page 8: ...ufacture EN ISO 15223 1 123 CE Mark EU 2017 745 Serial number EN ISO 15223 1 Unique Device Identification EU 2017 745 Medical Device Multi year inspection sticker Next test date marked by perforation EN 62353 Nameplate Manufacturer s identification address year of manufacture device designation serial number UDI number and device specific information EU 2017 745 ...

Page 9: ...itionally attached to devices with electrical components ISO 15223 1 3 2 Applied symbols for transport Figure Description Reference TOP top here DO NOT stack Protect from moisture Temperature range ISO 15223 1 Humidity ISO 15223 1 ...

Page 10: ...tient s will be instructed by qualified personnel Training with patients may only be carried out under therapeutic supervision The device may only be used by adults 14 years and older unsupervised children must be kept away from the device The application is done in a sitting position The application is made only with intact skin If you feel unwell or have sudden symptoms please stop training imme...

Page 11: ...d physiotherapy departments in hospitals rehabilitation clinics etc Depending on the indication health condition of the patient and treatment goal the devices can be used in any phase of rehabilitation 3 7 Clinical benefit Tergumed 600 devices support physiotherapeutic interventions The clinical benefit for the patient lies in the complementary use of the devices and the resulting improved muscle ...

Page 12: ... be used otherwise no liability will be accepted The device may only be opened by proxomed service or authorized personnel Do not place your hands between the moving bearings rollers 3 10 Combination with other products Tergumed 600 devices are equipped with the smart assist smart assist is an active medical device from proxomed Medizintechnik GmbH that contains software The smart assist was devel...

Page 13: ... device and the maximum permissible body weight of the user of 200 kg Small unevenness of the floor can be compensated for by means of the adjustable feet which can be attached to the unit Or a flat surface must be created by using suitable underlay material made of shims or heavy duty plastic The levelling materials should not be susceptible to rust When changing the position without dismantling ...

Page 14: ...it is important to ensure that the distance of at least 60 cm starting from the movement dimension to other devices is maintained during installation However the safety clearances may overlap Area up to next device Active Training area ...

Page 15: ...n Welded joints visual inspection Movement limitation if available as an option Accessories available functional Check for safe stand Make sure that aids accessories cables etc are not within the range of motion ATTENTION Before initial operation the devices should stand at room temperature for at least 24 hours CAUTION Before starting training check the locking pins for tightness Do not pull on t...

Page 16: ...ssion and shear forces Perform the movement slowly and in a controlled manner The intensity of the load should be chosen lightly at the beginning of the training Increase the load gradually to avoid overload and discomfort The equipment allows for a double legged or single legged or double armed or single armed workout If mobility is restricted or pain occurs immediately reduce the load and or the...

Page 17: ...nt capsule the focus can be on weight bearing with low training intensity before the training of special strength skills such as strength endurance or maximum strength begins with increasing intensity In order to be able to reproduce the training positions made by a therapist trainer during a later possibly independent training all adjustment devices are provided with scales and numbered alphabeti...

Page 18: ...l Flexion Intended use Tergumed 600 Lateral Flexion is designed for muscular stabilization of the lateral trunk Indications Sarcopenia Osteoporosis Nonspecific pain in the lower spine B C Armpit pads A Seat Femoral fixation D Start angle Weight Tower ...

Page 19: ...19 Settings A Seat height 13 cm stepless B Cushion inclination 5 cm 0 10 stepless C Pad width 16 cm 0 16 cm stepless ...

Page 20: ...20 D Start angle 60 120 5 à 10 E Femoral fixation stepless ...

Page 21: ...d use Tergumed 600 Rotation is intended for muscular stabilization of the trunk rotators Indications Sarcopenia of the trunk muscles Scoliosis A Seat Knee Supports Seat cushion D Start angle Padded arm B Footrest Weight Tower C Knee pads ...

Page 22: ...22 Settings A Seat height 13 cm stepless Seat width 19 cm 32 51 cm stepless B Footrest 7 cm 20 90 stepless ...

Page 23: ...23 C Knee pads 20 cm 0 20 cm stepless Knee support stepless D Start angle 55 125 6 à 10 ...

Page 24: ...24 Cushion arm inclination stepless ...

Page 25: ...25 7 5 General training settings Weight settings 5kg Main weights max 80 kg max 20 weights à 5 kg Fine weights optional 4 kg 4 weights à 1 kg ...

Page 26: ...e intervals are observed Component Maintenance interval Testing and maintenance Display daily Only use cleaning and disinfection agents suitable for the display Do not apply the agent directly but use a clean microfiber cloth Cushion after training Only use the disinfectants approved by the manufacturer to disinfect the upholstery A list of possible disinfectants can be found at https www serviceh...

Page 27: ... of liquids into the housing Damage to the training equipment Do not allow liquids to enter the inside of the machine during cleaning If tergumed 600 devices are operated with the smart assist accessory the electronic components contained in the smart assist must be disposed of by the operator via a disposal company when the device is decommissioned in accordance with the European WEEE Directive 2...

Page 28: ...scher service servicehelper meldung 2 This will take you directly to our servicehelper form There in addition to your personal contact information please provide the following information Indication of the product line Single device specification from the selected product line Indication of the serial number Short problem description o Occurrence of the problem when and where o Hardware or softwar...

Page 29: ...sor is designed for the exact reproducible individual training position in the device It enables quick and easy device adjustment on the tergumed 600 devices Available for Lateral Flexion Rotation Fine Weight Increments 4 x 1 kg item no 10692500 The Fine Weight Increment is intended for the targeted adjustment dosing of the training weight The adjustment is possible in two variants 4 x 1 kg 5 kg w...

Page 30: ...alker holder or water bottle holder depending on use Attach magnetic holder to load bearing metal cladding Available for Lateral Flexion Rotation Additional Platform item no 10331200 Extension of the floor area for a wide stance in the training position Available for Lateral Flexion Rotation ...

Page 31: ...6 x 92 x 163 126 x 115 x 163 tergumed 600 Rotation 400 kg 180 kg 160 kg 2 000 N 128 x 148 x 163 130 x 148 x 171 Ambient conditions Operation Temperature 5 to 45 Celsius Humidity 65 Transport and storage Temperature 10 to 45 Celsius Humidity 65 Requirements Medical Device Directive 93 42 EEC Product life 7 years as medical device Stationary training equipment EN ISO 20957 1 ISO 20957 2 Use class ac...

Page 32: ...ge for service but reserves the right to determine the type of service The following procedures are conceivable a The service is carried out on site by our service personnel b We send the requested spare part c We will send a replacement unit The defective parts will be returned to us by the customer within 48 hours Otherwise the delivered spare parts will be charged If the causes lie outside the ...

Page 33: ...1300 info proxomed ch www proxomed ch proxomed is a company certified by TÜV SÜD Product Service GmbH Changes proxomed reserves the right to change products if in our opinion these measures lead to an improvement in quality and function All illustrations in these instructions for use are approximate for typographical reasons we accept no liability for typographical errors Errors excepted User Manu...

Reviews: