iSCSI GbE to SAS/SATA RAID Subsystem
110
User Manual
5.5 Enclosure Management
“Enclosure management” allows managing enclosure information including “SES
configuration”, “Hardware monitor”, “S.M.A.R.T.” and “UPS”. For the enclosure
management, there are many sensors for different purposes, such as temperature
sensors, voltage sensors, hard disks, fan sensors, power sensors, and LED status. Due
to the different hardware characteristics among these sensors, they have different
polling intervals. Below are the details of polling time intervals:
1.
Temperature sensors: 1 minute.
2.
Voltage sensors: 1 minute.
3.
Hard disk sensors: 10 minutes.
4.
Fan sensors: 10 seconds . When there are 3 errors consecutively, controller
sends ERROR event log.
5.
Power sensors: 10 seconds, when there are 3 errors consecutively, controller
sends ERROR event log.
6.
LED status: 10 seconds.