iSCSI GbE to SAS/SATA RAID Subsystem
100
User Manual
“HI”
HIgh priority. (Default)
“MD”
MiDdle priority.
“LO”
LOw priority.
Bg rate:
“4 / 3 / 2 / 1 / 0”
Default value is 4. The
higher number the background priority of a VD is,
the more background I/O will be scheduled to
execute.
Read ahead:
“Enabled”
Enable disk read ahead. (Default)
“Disabled”
Disable disk read ahead.
AV-media mode:
“Enabled”
Enable AV-media mode for optimizing
video editing.
“Disabled”
Disable AV-media mode. (Default)
Type:
“RAID”
the virtual disk is normal. (Default)
“Backup”
the virtual disk is for clone usage.
Attach LUN
Attach to a LUN.
Detach LUN
Detach to a LUN.
List LUN
List attached LUN(s).
Set Clone
Set the target virtual disk for clone.
Clear Clone
Clear clone function.
Start Clone
Start clone function.
Stop Clone
Stop clone function.
Schedule Clone
Set clone function by schedule.
Set snapshot
space
Set snapshot space for executing snapshot. Please refer
to next chapter for more detail.
Cleanup
snapshot
Clean all snapshot VD related to the Virtual disk and
release snapshot space.
Take snapshot
Take a snapshot on the Virtual disk.
Auto snapshot
Set auto snapshot on the Virtual disk.
List snapshot
List all snapshot VD related to the Virtual disk.
More
information
Show Virtual disk detail information.
Summary of Contents for EP-4604D-G1S3
Page 1: ...iSCSI GbE to SAS SATA RAID Subsystem User Manual Revision 1 0...
Page 115: ...iSCSI GbE to SAS SATA RAID Subsystem User Manual 115...
Page 174: ...iSCSI GbE to SAS SATA RAID Subsystem 174 User Manual 8 Install 9 Installation succeeded...
Page 184: ...iSCSI GbE to SAS SATA RAID Subsystem 184 User Manual 34 Done...