Fibre to SAS/SATA RAID Subsystem
126
User Manual
The Hardware Monitor Information provides information about controller, enclosure 1 and
enclosure 2, such as the temperature, fan speed, power supply status and voltage levels.
All items are also unchangeable. When the threshold values are surpassed, warning
messages will be indicated through the LCD, LED and alarm buzzer.
Item Warning
Condition
CPU Temperature
> 90 Celsius
Controller Board Temperature
> 70 Celsius
HDD Temperature
> 65 Celsius
Fan Speed
< 1500 RPM
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.4V
Power 3.3V
< 3.0V or > 3.6V
DDR-II +1.8V
< 1.62V or > 1.98V
CPU +1.8V
< 1.62V or > 1.98V
CPU +1.2V
< 1.08V or > 1.32V
CPU +1.0V
< 0.9V or > 1.1V
DDR-II +0.9V
< 0.81V or > 0.99V
RTC 3.0V
< 2.7V