Part 2: Overview of display values and settings
Display
Range
19
Hot water
T-DHW RATED Current hot water set temperature
according to heating program and
operating mode
T-DHW
Current hot water temperature
RETURN
Exit level using
Ä
Heating circuit I / II
T-ROOM DES A Current room set temperature
according to heating program and
operating mode
T-ROOM
Current room temperature
HUMIDITY
***
)
Display of ambient air humidity (if
value is available)
T-POOL DES
*
) Swimming pool temperature setting
T-POOL
*
)
Current swimming pool temperature
T-DHW RATED
**
)
Hot water temperature setting
T-DHW
**
)
Current hot water temperature
T-FLOW RATED Current flow temperature setting
T-FLOW
Current flow temperature
N-OPT-TIME
Previous time required to heat up
with heat-up optimisation activated
RETURN
Exit level using
Ä
!
Display only appears if the sensor is connected and
the value is present in the system.
If the set value is not present it is masked out, or hyphens
appear in the display (- - - -).
T-DHW RATED (hot water set temperature)
Display of the currently valid value for control.
T-ROOM DES A (current value for set room
temperature)
If a control unit is connected there will be no display
"- - - -" => display on control unit
T-ROOM (room temperature)
Only if a sensor or a FBR is connected.
*
) These values only appear if the heating circuit is
programmed as a controller for the pool.
**
)These values only appear if the heating circuit is
programmed as a hot water circuit.
***)
These values only appear if an operating device is
connected and parameters have been set for the
corresponding heating circuit.
“- - - -„ => no humidity sensor available in control device