background image

OK!

NO!

Figure 12. Connecting fall protection system 

1. General information

Anchor point AT150 is an anchor device class A conforming to EN 795 and is designed for protection of one person. Anchor point AT150 may be used
only as personal protective equipment which protects a user against a fall from a height, and cannot be used for lifting loads. The device is made of
aluminium alloy using pressure casting technique. In accordance with EN 795:2012 type A strength of this point is min. 12 kN in any direction. The
device is designed for protection of one person.
The maximum load that could be transmitted in service from the device to the static construction - 9 kN. This is the actual force which the anchor
point transfers onto the structure to which it is attached when a fall occurs.
If the device is used as a part of a fall arrest system, the user must be equipped with an element limiting maximum dynamic forces applied on user
while arresting a fall to max. 6 kN.

2. Overall dimensions of anchor point AT150

See fig. 2

3. Time of usage

Maximum time of usage of correctly operating devices is unlimited.
The device must be withdrawn from use immediately and destroyed if it has been used to arrest a fall or there are any doubts concerning its
function.
NOTE: Maximum time of use of the device depends on intensity and environment of use. If the device is used in heavy conditions, being exposed to
frequent contact with water, sharp edges, corrosive substances, extreme of temperatures, it may be necessary to withdraw the device after only one
use.

4. Periodic inspections

At least once a year, after every 12 months of use, it is necessary to carry out periodic detailed inspection of the device.
Periodic inspection shall be carried out by service point authorized by the Manufacturer located at the following address:

PROTEKT Grzegorz 

Ł

aszkiewicz

u

l. Starorudzka 9

93-403 

Ł

ód

ź

or a competent person with adequate skills, trained in performing inspections of such equipment.

A trained person is a person who, based on own specialized education and adequate experience, has sufficient knowledge within installed protective
and rescue equipment, and is familiarized with applicable OHS regulations, guidelines and generally acknowledged technical rules to such extent
that is able to assess safety of use and correct application of protections.
After 5 years of use, it is recommended that periodic inspections are carried out by the manufacturer of the equipment or an entity authorised by
the manufacturer to carry out such inspections.
Before each use of the system check whether date of the next inspection is not expired. Do not use the device after this date. Before each use of the
system visually check the system for its integrity and technical condition and whether steel cable is tensioned.

If any defect or lack of integrity is found, do not use the point. If any doubts arise as for the use of the equipment, please contac. t the manufacturer
and never repair the equipment on your own!
A system which has been used to arrest a fall must be withdrawn from use immediately!
The system which has been used to arrest a fall may be admitted for use again after a detailed inspection is carried out by the manufacturer or an
authorised service point.

2/5

 READ AND UNDERSTAND INSTRUCTION MANUAL 

BEFORE USING THE EQUIPMENT 

 

Summary of Contents for AT150

Page 1: ...ing holes for anchor point AT150 Figure 10 Embedding throughbolts in concrete Figure 11 Tightening anchor point using torque wrench Figure 7 Estimation of maximum permissible unevenness of concrete structure 1 5 EN795 Type A Standard reference Before use read the instruction manual MM YY month year Date of manufacture Max 1 Maximum number of users AT150 Reference number of device Manufacturer s de...

Page 2: ... inspections At least once a year after every 12 months of use it is necessary to carry out periodic detailed inspection of the device Periodic inspection shall be carried out by service point authorized by the Manufacturer located at the following address PROTEKT Grzegorz Łaszkiewicz ul Starorudzka 9 93 403 Łódź or a competent person with adequate skills trained in performing inspections of such ...

Page 3: ... calculated and be no less than 12kN Fix anchor point AT150 in the drilled holes using M12 bolts of adequate length and strength class accordingly for galvanized bolts strength class no lower than 8 8 for stainless steel A2 and acid resistant steel A4 bolts strength class no lower than 70 Figure 5 Bolts should be tightened using a torque wrench by applying a torque of no more than 40Nm Increasing ...

Page 4: ...ndition and safety of users which is dependant on the equipment functionality and durability During periodic inspection it is necessary to check the legibility of all the equipment markings identity label of the device All information on protective equipment name serial no purchase date and date of first use name of user information on repairs and inspections and withdrawal from use must be provid...

Page 5: ...the date of purchase of the device If a defect is found in any part the warranty and guarantee period for this part is extended by the time of repairs and effective removal of the defect found The warranty covers Defects in material Structural defects Anti corrosion coating defects In order to keep the warranty it is necessary to follow procedures of periodic inspections specified in item 4 of the...