background image

19.0 Ordering Information

Please use the following product codes when placing an order for the Protégé® EliteSuite® Eclipse 
LED Keypad. 

•  ELT-KLES

Manuals and literature are available at the Integrated Control Technology website in the 
documentation section. If you require manuals on CD-ROM please request a Resource CD-ROM 
from the website. 

48

Summary of Contents for EliteSuite Eclipse

Page 1: ...ELT KLES Protégé EliteSuite Eclipse LED Keypad Installation Manual ...

Page 2: ...smitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited EliteSuite and the EliteSuite Logo are registered trademarks of Integrated Control Technology Limited All other brand or product names are trademarks or registered trademarks o...

Page 3: ...tor 12 6 4 Message Indicator 12 6 5 Zone Display 12 7 0 Audible Tones 13 7 1 Configuration Tone 13 7 2 Entry Request Tone 13 7 3 Rejection Tone 13 8 0 Keypad Operation 14 8 1 Second Function 15 9 0 Device Configuration 16 9 1 Entering Device Configuration Mode 16 9 2 Address Selection Menu 1 17 9 3 Device Options Menu 2 17 9 4 Backlight Level Menu 3 18 9 5 Firmware Version Menu 4 19 9 6 Device Def...

Page 4: ...13 3 Zone Options 30 14 0 Configuration via Protégé 31 14 1 Connecting to the Module 31 14 2 General Setup Tab 32 14 3 Users Setup Tab 33 14 4 System Setup Tab 35 14 5 Options Setup Tab 37 15 0 Quick Reference 41 15 1 Configuration Menu 41 15 2 Installer Menu 42 15 3 User Menu 44 16 0 Mechanical Diagram 45 17 0 Technical Diagram 46 18 0 Technical Specifications 47 19 0 Ordering Information 48 20 0...

Page 5: ...ative this keypad fits in with modern décor while still providing a user friendly interface to the Protégé EliteSuite alarm functions Operating in the Condominium Control mode the Protégé EliteSuite Eclipse LED Keypad provides a complete standalone 8 zone 8 user local alarm system The current features of the Protégé EliteSuite Eclipse LED Keypad include 4x onboard zones 8 with duplex zone operatio...

Page 6: ...tégé System Management Suite Enterprise Edition PRT SMGT PRO Protégé System Management Suite Professional Edition PRT SMGT STN Protégé System Management Suite Standard Edition PRT SMGT 1U Protégé System Management Suite Single Client License Edition Product Code Description ELT TLCD Protégé EliteSuite Touchscreen Keypayd ELT KLCD Protégé EliteSuite Alphanumeric LCD Keypad ELT KLED Protégé EliteSui...

Page 7: ...d the rear case half against the wall and mark the mounting holes and cable entry area The cable entry area should align with a hole cut through the plaster wall board Cables are intended to be run inside the wall Use appropriate screws not supplied to affix the case to the wall Step 4 Run the wiring Refer to later sections of this manual for the electrical connections Leave about 20cm 8 of wire p...

Page 8: ... using a keyed 10 position snap lock connector The 10 way wiring loom connection uses the following color coding Figure 2 Wiring Loom Color Coding and Function YELLOW GRAY PURPLE ORANGE BLACK WHITE BLUE BROWN GREEN RED 0V 12V System controller network communica on terminals and module network NA NB ZONE 1 1 2 ZONE 2 3 4 PGM 1 OUTPUT ZONE 3 5 6 ZONE 4 7 8 0V Zone inputs and PGM Output Figure 1 Cond...

Page 9: ...nnection to the system controller uses the network communication RS 485 interface The Protégé EliteSuite Eclipse LED Keypad also requires power to be supplied to the N and N terminals KEYPAD 1 KEYPAD 2 KEYPAD 250 12V 0V NA NB 12V 0V NA NB 12V 0V NA NB N N NA NB External 12V power supply If more than one power supply is used ensure that the 0V is connected to all other power supply devices powering...

Page 10: ...ion settings Refer to the General Options section on page 23 for programming of the zone configuration When using a tamper input on a device the tamper contacts must be normally closed and wired in series All resistors required to wire the zone configurations are provided with the Protégé EliteSuite Eclipse LED Keypad in the accessory bag Figure 5 Zone Input No Resistors Figure 4 Zone Input No Res...

Page 11: ...Tamper N C Tamper Zone 1 N C Zone Contact Resistors should be located at the device a ached to the zone 0V 1k 1k 2k4 2k4 Zone 3 N C Zone Contact Zone 2 3 4 PURPLE ORANGE BLACK Zone 2 N C Zone Contact Zone 4 N C Zone Contact Zone 3 5 6 N C Tamper N C Tamper Zone 5 N C Zone Contact Resistors should be located at the device a ached to the zone 0V 1k 1k 2k4 2k4 Zone 7 N C Zone Contact Zone 4 7 8 YELLO...

Page 12: ... is shown as all zones closed A Fire Loop Trouble will be shown when the zone is tampered Fire Zones that are installed in Duplex mode operation are not recommended Fire Zones should always be connected using the EOL resistor method 1k and 1k as this provides both open and short circuit monitoring The Protégé EliteSuite Eclipse LED Keypad is designed to be used with non latching smoke detectors If...

Page 13: ...ay or other interface device to this open collector output for activation of ancillary devices The behaviour of this Output can also be inverted in the programming Refer to the General Options section on page 23 for details on PGM programming The PGM Output of the Protégé EliteSuite Eclipse LED Keypad is designed for a maximum current of 100mA If using it to trigger an external siren then a relay ...

Page 14: ...ng regularly The system is in an alarm state caused by activation of zone s while armed or the use of the Panic or Medical Alarm keys Flashing three flashes then pausing The system is in an alarm state caused by activation of fire zone s You must enter your User code to acknowledge this alarm Flashing a brief pulse every 2 5 seconds The last alarm that occurred has been stored in the system memory...

Page 15: ...There is a trouble condition present State Description Off Normal operation Flashing The concierge is requesting your attention 6 2 Ready Indicator State Description Off One or more zones in the system are open and the system cannot be Regular Armed On The system has all zones closed and is ready to be armed Flashing The system has begun arming and is in Exit Delay mode to allow exit from the prem...

Page 16: ...cessfully entered on the keypad or when the system switches to a new status mode the keypad generates a series of four audible tones 7 2 Entry Request Tone When navigating the menu structure a series of two audible tones will sound when you are expected to enter a value Example Enter a Zone Number User Number User code or change a setting 7 3 Rejection Tone When the system times out or when an ope...

Page 17: ... arm the system FNC The Second Function key enables the second function of four of the number keys Refer to the following section for details MENU To access Setup menus press the Menu key then enter a valid four digit User code The Menu key is also used for navigating the menu structure 0 9 NUMBER The number keys are used for entering User codes or configuring system settings CLEAR The Clear key i...

Page 18: ...e desired key to select STAY FORCE MEMORY or BYPASS Pressing any other key will cancel second function mode Some key actions require pressing and holding the function keys for two seconds e g Fast Force Arming In this case it is not required but not wrong to press the SECOND FUNCTION key first Example Simply pressing and holding the 2 key for two seconds will select Fast Force Arming if this optio...

Page 19: ...een entered You can then press the key corresponding to the menu required as detailed in the following sections 9 0 Device Configuration 9 1 Entering Device Configuration Mode Before the Protégé EliteSuite Eclipse LED Keypad module will communicate it must be assigned an address and programmed with specific options as to how it will operate This is achieved by accessing the Device Configuration me...

Page 20: ...RESS 1 ADDRESS 2 ADDRESS 3 The device will beep four times to indicate that it has changed the address All three digits must be entered when programming an address This means that for addresses below 100 you must enter 0 then the 2 digits of the address For addresses below 10 you must enter 0 0 followed by the address digit 9 3 Device Options Menu 2 The Device Options set options that relate to th...

Page 21: ...sequence 3 The current Backlight setting will be displayed as a sequence of three Number LED s lighting one after the other corresponding to each of the three digits of the setting To Change the Current Backlight Setting Step 1 To change the current backlight setting enter the following key press sequence 3 SETTING 1 SETTING 2 SETTING 3 The device will beep four times to indicate that it has chang...

Page 22: ...ypad microprocessor enter the following key press sequence 4 2 The keypad microprocessor firmware version will be displayed as a sequence of four number LED s lighting one after the other The first two digits are the major version number and the second two digits are the minor version number 9 6 Device Default Menu 5 Step 1 To Default all the Device Options enter the following key press sequence 5...

Page 23: ...ormed on the system controller and the user code at system controller user location 3 UN00003 has been changed The code that is entered in this setting is now the local Installer code This code is programmed system wide when an update is performed To disable the Installer Code on all Protégé EliteSuite Eclipse Keypads recommended delete the code for User UN00003 by following the instructions in th...

Page 24: ...equence 1 1 TIM 1 TIM 2 TIM 3 Where TIM 1 to 3 are the Timer value digits entered using the 0 to 9 number keys Programming the Entry Delay Timer to 0 will result in no entry delay operation for any zone that has been assigned the entry delay Zone Type Example The sequence 1 1 0 3 0 sets the timer to 30 seconds 11 2 Exit Delay Timer Menu 1 2 The Exit Delay Timer is programmable from 000 to 255 seco...

Page 25: ...ately arm the EliteSuite System Example The sequence 1 2 0 4 5 sets the timer to 45 seconds 11 3 Alarm Siren Timer Menu 1 3 The Alarm Siren timer is programmed from 000 to 250 minutes default 4 minutes To View the Timer Value Step 1 To view the Timer value enter the following key press sequence 1 3 The Timer value will be displayed as a sequence of three number LED s lighting one after the other c...

Page 26: ...n 1 If Duplex Zone Option 2 is not enabled then Option 1 will set the Zone Input Configuration EOL or NO EOL EOL requires the use of 2x 1k resistors to provide Short Alarm Closed and Tamper monitoring NO EOL provides alarm and closed monitoring Enabled EOL resistors are used 2R Mode 2 zones Disabled NO EOL resistors are used 2 zones Option 2 Duplex Zone Operation If Option 2 is set Option 1 does n...

Page 27: ...nabled with the alarm siren time activation or fire alarm activation Disabled the PGM Output will not change state regardless of the alarm status Option 7 PGM Output Follows Area Status Enabled the PGM Output will be enabled with the alarm siren time activation or fire alarm activation Disabled the PGM Output will not change state regardless of the alarm status Option 8 PGM Output Inversion Enable...

Page 28: ...nabled the system can be fast armed by pressing and holding the ARM key Disabled fast arming is disabled Option 2 Allow Fast Stay Arming Enabled the system can be fast stay pressing and holding the STAY key 1 Disabled fast stay arming is disabled Option 3 Allow Instant Arming During Stay Exit Delay Enabled the system will allow the STAY key 1 to be pressed and held during the exit delay of a stay ...

Page 29: ...s The available options are Option 1 Report Arming and Disarming Enabled the Protégé EliteSuite Eclipse LED Keypad will send a message to the system controller when the system is armed or disarmed If this option is disabled the current status of the Protégé EliteSuite Eclipse LED Keypad will not be valid It is recommended this and the Report Alarm options are always enabled Disabled no message wil...

Page 30: ...the system will report when the local installer code is used to gain access to the local installation options Disabled no message will be sent when the installer access s the installer menu Option 7 Report Extended Information Enabled the system will report extended information such as the device tamper and fire loop trouble conditions These conditions do not generate an alarm in the system locall...

Page 31: ...rm state when this occurs and if enabled the PGM Output will be activated Disabled the 1 3 keys will not cause any alarm Option 2 4 6 Medical Alarm Enabled the system will send a Medical alarm to the front desk when the 4 6 keys are held for a period of 2 seconds The keypad will enter alarm state when this occurs and if enabled the PGM Output will be activated Disabled the 4 6 keys will not cause ...

Page 32: ...pressing the number key corresponding the desired Zone Type When the number key is pressed the number LED will stay lit to indicate the selection Step 2 Press the ENTER key to confirm your selection Pressing the MENU key will abort the operation without saving any changes You must select a Zone Type from the following list Zone Types 1 Disabled Zone is disabled does not function in the system 2 De...

Page 33: ... exit the menu system The available options are Option 1 Bypass Allowed Enabled the zone can be bypassed A fire zone can never be bypassed regardless of the bypass setting Disabled zone can not be bypassed Option 2 Stay Zone Enabled the zone is set as a Stay zone When the system is armed in stay mode this zone will not generate an alarm Disabled the zone is not a Stay zone Option 3 Force Zone Enab...

Page 34: ...tep 2 Select the Programming Condominiums tab from the top of the Condominiums section Step 3 Right click on Condominium where corresponds to the address that was set on the module Step 4 Select Properties from the pop up window A pop up box will appear which will show the progress while uploading the current settings from the controller If this box does not appear and the Condominium Properties w...

Page 35: ...ing The Data field is for general notes and not intended for any specific data The Challenge Question is used in the case where a Master User needs to identify themselves to the property manager The Account Code is the code that will be stored in the controller and used for reporting purposes to identify the specific keypad Figure 15 General Setup 14 2 General Setup Tab 32 ...

Page 36: ...Suite Eclipse LED Keypad can support up to 8 separate users Under the two tabs Users 1 to 4 and Users 5 to 8 the users individual settings can be configured The settings are Figure 16 User Setup 14 3 Users Setup Tab 33 ...

Page 37: ...Setup menu and modify the codes and options of all other users When disabled prevents access to the User Setup menu Disarm on Single Badge Not relevant to and not used by the Protégé EliteSuite Eclipse LED Keypad Arm on 3 Badge Not relevant to and not used by the Protégé EliteSuite Eclipse LED Keypad 3 Badge Latch Door Toggle Not relevant to and not used by the Protégé EliteSuite Eclipse LED Keypa...

Page 38: ...The Protégé EliteSuite Eclipse LED Keypad can support up to 8 separate zones allocated to one area These are wired in to the keypad as shown in section 43 and are configured using the System tab as follows 14 4 System Setup Tab ...

Page 39: ... fire zone procedures to prevent a full fire alarm from being activated Zone1 Bypass When enabled the zone can be bypassed A fire zone can never be bypassed regardless of the bypass setting When disabled the zone cannot be bypassed Zone1 Stay When enabled the zone is set as a stay zone When the system is armed in stay mode this zone will not generate an alarm When disabled the zone is not a Stay z...

Page 40: ...Figure 18 Options Setup The Options tab allows for the configuration of settings that are relevant to all users and all zones 14 5 Options Setup Tab 37 ...

Page 41: ...n exit delay condition if the power to the EliteSuite device was turned off during an exit delay cycle or if the system was armed If the system was in alarm or was in the entry delay state then it will go into the alarm state when power is restored Reader Network Enabled Not relevant to and not used by the Protégé EliteSuite Eclipse LED Keypad PGM Follows Alarm Status When enabled the PGM Output w...

Page 42: ...options are always enabled Report alarm Activation When enabled the Protégé EliteSuite Eclipse LED Keypad will send a message when an alarm occurs on the EliteSuite System This also enables the sending of the alarm silenced and alarm timed out messages Report Zone Bypassed When enabled the system will report when the EliteSuite system is armed with zones that have been bypassed Report Zone Fault W...

Page 43: ...keys are held for a period of 2 seconds The Protégé EliteSuite Eclipse LED Keypad will enter alarm state when this occurs and if enabled the PGM Output will be activated Panic 7 9 Generate Fire Alarm When enabled the system will generate a local Fire alarm on the Protégé EliteSuite Eclipse LED Keypad when the 7 9 keys are held for a period of 2 seconds and also alert the central station and on sit...

Page 44: ...the current address 1 A1 A2 A3 Set the current address 2 toggle options Modify system options Option Description Default 1 Reserved Disabled 2 Enable Device Tamper Disabled 3 8 Reserved Disabled 3 View the current Backlight setting 3 B1 B2 B3 Set the current Backlight setting 4 1 View the main processor firmware version 4 2 View the keypad processor firmware version 5 Default the system 41 ...

Page 45: ...le condition Disabled 4 Power up disarmed Disabled 5 Reserved Disabled 6 PGM output follows alarm state Enabled 7 PGM output follows area state Disabled 8 PGM output inversion Disabled 2 2 toggle options Arming Options Option Description Default 1 Allow Fast Regular arming Enabled 2 Allow Fast Stay arming Enabled 3 Allow Instant Arming during Stay exit Enabled 4 Allow Fast Force arming Enabled 5 8...

Page 46: ...ype Type Description 1 Disabled 2 Delay Zone has an entry delay 3 Follow Instant but not if another Zone has already triggered the entry delay 4 Instant Zone will trigger instantly 5 24hr Zone will always cause an alarm immediately 6 Fire Zone will trigger a Fire alarm instantly 7 Fire delay Zone will trigger a Fire alarm after 30s delay 8 Reserved select zone option Select Zone Option Option Desc...

Page 47: ...zones on off Select Chime Zones 2 Clear message 3 View Memory alarm 3 Force Clear Memory alarms 4 View trouble conditions Trouble Description 0 3 Reserved 4 Fire loop 5 Reserved 6 Cover tamper 7 Zone fault 8 Host Comms 5 User 1 View User code 5 User 1 User code User code Change User code 5 User 1 Force Force Delete User code 44 ...

Page 48: ...nes the essential details needed to help ensure the correct installation of the Protégé EliteSuite Eclipse LED Keypad Arm Armed Power Trouble Ready Message Tamper Switch Case Disassembly Tab Zone Indicators Mounting Holes Wiring Loom Figure 19 Mechanical Diagram 45 ...

Page 49: ... essential details needed to help ensure the correct installation of the Protégé EliteSuite Eclipse LED Keypad 40mm 4 5mm diameter 54mm ELT KLES 16 5mm 10mm 10 5mm 17 5mm 37 5mm 57 5mm 64 5mm 75mm 34 5mm 82 5mm 100 5mm 107mm 117mm 97mm 48mm Figure 20 Technical Diagram 46 ...

Page 50: ...ing Voltage 11 5VDC to 24VDC Operating Current 50mA 80mA max User Interface Display Keypad Combined 15 key capacitive touch keypad with 8 zone status LED S and 3 system status LED S Zone Inputs System Zones 4 standard or 8 using Zone Duplex mode Zone Inputs Enclosure Tamper PCB mounted external micro switch assembly PGM Outputs 1 open collector negative Output 50mA max Open collector Output for ge...

Page 51: ...n placing an order for the Protégé EliteSuite Eclipse LED Keypad ELT KLES Manuals and literature are available at the Integrated Control Technology website in the documentation section If you require manuals on CD ROM please request a Resource CD ROM from the website 48 ...

Page 52: ...the Seller cannot guarantee the performance of the security system Seller s obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including withou...

Page 53: ...This page has been intentionally left blank ...

Page 54: ...This page has been intentionally left blank ...

Page 55: ...This page has been intentionally left blank ...

Page 56: ...d Phone 64 9 476 7124 Fax 64 9 476 7128 Email support incontrol co nz www incontrol co nz Designers and manufacturers of integrated electronic access control security and building automation products Designed and manufactured by Integrated Control Technology Limited Copyright Integrated Control Technology Limited 2003 2010 All rights reserved 227 4185 001 ...

Reviews: