9.0  Technical Specifications 

Parameter 

Operating Conditions / Limitations 

Power Supply 

20 to 28V

DC

, Minimum 2A

DC

: Approved to EN54 Part 4: (Latest) 

Power Supply Fuse 

1.6A  

Voltage Operating Range 

20 to 28 V

DC 

Maximum Current 
Consumption 

1.1A

DC

 maximum at 24V

DC

 (blower set to 100%, 4 Pipe Detector) 

Loop Protocol 

Protec Algo-

tec™ 6000 

Loop Isolator 

On board consult Protec DEL2110 for details 

Loop Quiescent Current 
Consumption 

0.7mA 

Fault Contact 

Rated at 30 V

DC

 1 A

DC

 maximum [Normally closed] 

Input Contacts [1 to 3] 

3 Programmable monitored inputs 30 V

DC 

[Active Low] 

Max applied voltage 30 V

DC

, Open Circuit Voltage ~16 V

DC 

Closed Circuit Resistance 1k5

Ω 

Output Contacts [1 to 5] 

5 Programmable Clean Contacts Outputs 

Rated at 30 V

DC

, 1 A

DC

 max [Normally open] 

Power Supply Input Monitor 

Normal 24V

DC

 Input, Fault 

≤ 2.5V

DC 

Temperature Range 

0°C to 45°C ambient 

Humidity Limit 

0 - 95% non-condensing ambient 

Indicators 

Power   

[Green LED] 

Fault 

 

[Amber LED] 

Pre-Alarm  

[Amber LED] 

Alarm/Fire  

[Red LED] 

7”  LCD touch screen display 

Water Requirements 

Distilled (or Triple De Ionised Water), replenished as required, dependent 
upon environment. 

Sensitivity Range 

0.002u/l³. 10,000 particles per cc to 10 million particles per cc.  

Optical Sensitivity Range 

0.1%/m to 20%/m    

Sensitivity Settings 

7 day programmable settings with daily time zones. 

Sound Pressure Levels 

72dB [peak] (Blower at 100%) 

Airflow Monitoring 

High and Low airflow monitoring 

Airflow Monitoring Range 

± 5% to 50% respectively. For EN54 Part 20 compliance, Unit tolerance set 
to ≤ 20% set by the PC commissioning tool. 

Airflow Velocity Range 

0.5 m/s to 6 m/s 

Event Log 

256 events stored on FIFO basis 

Environmental History 

Typically 1 Month depending on activity 

IP Rating 

IP30 

Cable Access 

10x 20mm replaceable knockouts 

Cable Termination 

Screw terminal blocks 

(0.2 - 2.5 mm

2

, 30 - 12AWG) 

Connectivity 

TCP/IP Networking Protocol RJ45 Socket connection 

USB type B Socket connection 

Pipe OD 

 

25mm 

Pipe Length Maximum 

Recommend to consult the pipe calculation program 

User code (default) 

1442 

 

 

 
 

Summary of Contents for CIRRUS HYBRID

Page 1: ...ec Fire Detection plc Protec House Churchill Way Nelson Lancashire BB9 6RT ENGLAND 44 0 1282 717171 www protec co uk sales protec co uk PROTEC CIRRUS HYBRID ASPIRATING SMOKE DETECTION SYSTEMS USER MAN...

Page 2: ...N93 601 00 Issue 1 Page 2 of 25 Protec Fire Detection PLC 2015 Document Revision Details Issue Modification Detail Author Date 01 Document Creation RB 15 11 15...

Page 3: ...16 4 11 Viewing the Network information 16 4 12 Viewing the Event log 17 4 13 Pipe Map 17 5 0 RESPONSE TO AN ALARM 18 5 1 Pre alarm 18 5 2 Fire 18 5 3 Silencing the Alarm 18 5 4 Resetting the Alarm 1...

Page 4: ...ctured in conformance with the requirements of all applicable EU council directives and regulations Electrical or electronic devices that are no longer serviceable must be collected separately and sen...

Page 5: ...tandard dictating aspirating smoke detector design practice EN54 parts 20 2 0 User Responsibilities The registered owner of the fire alarm system has specific responsibilities regarding the installati...

Page 6: ...ion water condenses onto the small particles and forms a cloud Consequently the thermally generated particles cause many droplets to form into the cloud which is then detected by the measuring system...

Page 7: ...e the hybrid system utilises the cloud chamber as the primary detector which is not affected by dust with a boost signal when the scatter chamber detects the smoke Using the two technologies allows th...

Page 8: ...ipe 4 B Air Exhaust Return C LCD Touch Display D LED Status Indication E Cable Entry Knock Outs F Cable Gland 20mm G Fire Protected Cable H Product Manufacture Label 4 0 Cirrus Hybrid General Componen...

Page 9: ...on 1 B2 SCD Location 2 B3 SCD Location 3 B4 SCD Location 4 C Terminal Connection Board D Earth block E Vacuum Pump Assembly F Water Bottle G Vacuum Silencer H Pipe Scanning Unit 1 I Cloud Chamber Asse...

Page 10: ...nts Key A Rear Display Cover Moulding B Label MAC address SCD Position C Front Display Assembly Securing Screws D Ribbon Cable to Terminal Board E Hinge Pin F Ribbon Cable to Cloud Chamber and Zone Sc...

Page 11: ...ted by the coloured markers The current status of fires and faults are shown under the Detector Status title bar below the dials For quick navigation there are a series of icons permanently displayed...

Page 12: ...correct for either user the following message will appear and the icon will change colour from the green to a red User Level Access Code default 1 4 4 2 If the code is incorrect the following message...

Page 13: ...4 m CFS Combined Fire and Smoke Mathematical algorithm Time zone Providing timezone is enabled the home page will display to indicate the pipe night mode is activated Silence and reset The Cirrus Hybr...

Page 14: ...and side Ensure you are logged in as user to edit the time Set the time either by the rotating the clock minute hand by selecting and dragging or using the symbols to increment decrement the hours min...

Page 15: ...quick navigation The airflow menu displays the current airflow for each pipe the fault tolerance monitoring for each pipe the airflow ignore box for each pipe the fan speed configurable from 5 to 100...

Page 16: ...cess level code can be changed to a custom number of digits ranging from 1 to 9 4 11 Viewing the Network information Click the network icon for quick navigation The network menu displays Protec Loop s...

Page 17: ...rid stores all fire faults and events in the event log The event log can store a maxium of 256 events In the user access level 16 latest events are viewable 4 13 Pipe Map Click the site pipe icon for...

Page 18: ...e Cirrus Hybrid unit will display the pipe text of the pipe in alarm and the fire alarm level 1 2 or 3 in the detector status list The fire alarm level LED will illuminate and the buzzer will pulse fa...

Page 19: ...ent airflow value At the time of commissioning when the pipe configurations are complete the airflow reading must be zeroed The Cirrus Hybrid sets the normalised zeroed value to 100 If the airflow rea...

Page 20: ...s means that the unit is not purging correctly User Action Contact a Protec operative or a Protec distributor 6 11 High Optical Background The optical analogue value has increased outside the operatio...

Page 21: ...e or a Protec distributor 6 18 Processor Fault The internal processor hardware has unexpectedly reset Cleared only on a full power cycle This is indicated if a problem has been detected with the micro...

Page 22: ...m the selected pipe While unit is in this state it will display a Pipe Scan Halted fault until the pipe hold function is disabled User Action Contact a Protec operative or a Protec distributor 6 25 He...

Page 23: ...creased above the stable background threshold Time Set The internal system time has been set Faults Cleared All system faults have been cleared system returned to normal status Event Log Cleared The e...

Page 24: ...d correct operation the system must be checked Daily by the User Every three months by Protec Fire Detection or an authorised representative Whenever building alterations have been performed which cou...

Page 25: ...n condensing ambient Indicators Power Green LED Fault Amber LED Pre Alarm Amber LED Alarm Fire Red LED 7 LCD touch screen display Water Requirements Distilled or Triple De Ionised Water replenished as...

Reviews: