TROUBLESHOOTING GUIDE
SYMPTOM
CAUSE
SOLUTION
3. The valve fails to
draw brine
4. The valve cycles
continuously
5. Excessive water in
the brine tank
6. The valve fails to
refill the brine
tank
1. Low operating pressure.
2. The injector is plugged.
3. The injector filter is plugged.
4. The drain line is restricted.
5. The brine line is restricted.
6. Leak in the brine line.
7. Not enough water in the brine tank.
1. Defective or shorted microswitch(es)
1. The valve fails to draw brine.
2. Improper or missing brine refill flow control.
3. Leak between the rotor and seal disk.
1. Blockage in the brine line or brine valve.
1. Remove the blockage.
2. Verify that the flow control is installed and
properly sized.
1. Refer to SYMPTOM #3.
1. Replace the microswitch(es)
7. Refer to SYMPTOM #6.
6. Check the brine line and connections for
leaks.
5. Check the brine line for kinks or restrictions.
4. Check the drain line for kinks or restrictions.
Verify that the backwash flow control is free
of debris.
3. Clean the injector filter.
2. Clean the injector.
1. Verify the operating pressure (20 psi min.).
3. Check the rotor and seal disk; replace if
necessary.
2. Improper or missing brine refill flow control.
3. Plugged brine refill flow control.
3. Remove the debris.
2. Verify that the flow control is installed and
properly sized.