SYSTEM START UP INSTRUCTIONS
1. Turn the main shutoff valve until it is just barely open. The unit will release any air trapped inside the
valve, without agitating the mineral.
2. Verify that the control is in the Service Mode (time of day and gallons remaining).
3. Start an immediate regeneration (see page 11).The first step will be backwash. Allow the water to
flow from the drain until all the air has purged from the system.
4. Open the main shutoff valve fully.
5. Advance (scroll) the control to the brine cycle. The system will draw water from the brine tank.
Remove the brine line and check for suction. If no suction is present, please refer to the trouble-
shooting guide on page 19.
6. Advance (scroll) the control to fill/rinse. Allow the system to fill the brine tank.
7. Use the SCROLL BUTTON to advance the control back to the Service Mode (time of day and gallons
remaining).
8. The installation is now complete.
SANITIZING THE SOFTENER
Note: The unit may be sanitized with or without salt in the brine tank.
After the installation is complete, the following procedure can be used to sanitize the water conditioner:
1. Mix a 3/4 cup of common (unscented) 5.25% household bleach with 1 quart of water. Pour this
solution into the brine well.
Note: Do not pour undiluted bleach into the water conditioner.
2. Initiate a manual regeneration. The solution will be drawn into the water conditioner during the
regeneration process.
3. When the regeneration is complete, the water conditioner has been sanitized.
14
Summary of Contents for SIZE 1.0
Page 15: ...15 VALVE EXPLODED VIEW ...