10
Installer Guide
These setup steps allow the user to monitor
equipment runtimes and program service alerts.
Service alerts are displayed in the scrolling
marquee.
How to Change Settings in the Setup Screens
To enter Advanced Setup, press the
SETUP
button, then press
MODE
. Use the
WARMER
or
COOLER
buttons to adjust the value of your selection. Press
MODE
to advance to the next
setup step. Press
SETUP
again to leave the setup screens.
WARMER
COOLER
MODE
Set
Clock
WARMER
COOLER
MODE
Set
Clock
Current Service Filter Runtime Hours
(Setup Step 9) - This counter keeps track of the
number of hours of fan runtime in the Heating mode, Cooling mode, and in stand alone
Fan operation. Press
FAN
to reset.
Current Service Filter Calendar Days
(Setup Step 10) - This counter displays the total
number of calendar days that have elapsed since the counter was reset to help the user
track filter usage. Press
FAN
to reset.
Set Service Filter Runtime Hours
(Setup Step 16) - This timer allows the user to specify
the number of hours the fan will run before the “Replace Filter” alert will be displayed.
Press COOLER continuously until 0 is displayed to disable this alert.
Set Service Filter Calendar Days
(Setup Step 17) - This timer allows the user to specify
the number of calendar days that will elapse before the “Replace Filter” alert will be
displayed. Press COOLER continuously until 0 is displayed to disable this feature.
Press and hold FAN
to clear service alert
messages from the
scrolling marquee.
FAN
ON |AUTO
Service Filter Runtime (Setup Steps 9-10, 16-17)
PSP4273_Installer man.indd 10