Chrome Tap

Counter Top

Black Rubber Washer

Black Locating Washer

Brass Nut

Stud

Pushfit 
Connector

Blue Tubing

Locking Washer

FITTING INSTRUCTIONS:

Fitting The Pre-Plumbed RO System

Use the bracket as a template to mark the position of the unit on a suitable wall or cupboard panel. Allow a minimum 
of 40mm clearance below the filter bowls to allow for filter change out. Drill and plug two holes and screw in 2 

screws (not supplied) allowing the screw heads to protrude from the wall by approx. 
5mm. Place the bracket over the screws and slide to left or right (as preferred) to lock 
bracket in position.

Fitting The Tap

 

Select a suitable position on the work top or corner of the sink. Before drilling the 

hole,  check  there  is  nothing  directly  underneath  that  could  be  damaged  i.e. 
water  or  waste  pipes,  cables  etc.  Also  make  sure  that  there  is  room  for  the 
locating washer and that you can physically reach the tap stud to connect the 

brass nut. Use a centre punch to mark the location of the hole to be drilled. Drill 
a  3mm  pilot  hole.  Enlarge  the  hole  to  11mm.  If  you  are  drilling  through 

stainless steel, deburr and rough edges around the hole. Wipe clean with a soft 
cloth. Check that the tap stud fits easily through the hole. Secure the push fit 

connector  and  firmly  push  one  end  of  the  blue  pipe  into  the  collar  within  the 

push-fit  connector.  Push  the  other  end  of  the  blue  tubing  into  the  push  fit 
connector fitted to the post carbon filter housing.

Note: 

Some taps are supplied 

with  the  blue  tubing  already  permanently  fitted.  The  tap  has  two  ‘ON’ 

positions. Lift the lever up for continuous flow. Press the lever down for flow 
that ceases when the lever is released.

Fitting The Saddle Tapping Valve

Although not essential, we recommend that you turn off the cold water stopcock 
and relieve the water pressure by opening cold water tap. If the stopcock is under 
the  sink,  fit  the  valve  after  the  stopcock.  The  valve  must  be  fitted  on  the  cold 
water supply only, (if you are uncertain, run the hot tap for a minute and feel the 
pipes under the sink to distinguish the cold pipe).
Do not fit the valve on a bend, a join or where there is solder on the copper pipe. 
Attach the clamp around the pipe and tighten the clamp bolt to ensure a water 
tight seal. Do not over tighten the clamp bolt as this may distort the water pipe. 
Firmly push the open end of the red tubing attached to the saddle tapping valve 
into the collar on the front of the pre carbon filter housing.

Note: 

Later designs have the red tubing already permanently fitted to the valve. 

The saddle tapping valve supplied with the RO-Pro System is designed to comply 
with British plumbing codes.  (See ‘System Start Up’ Section for further details 
regarding the saddle tapping valve.)

 

Note: 

Later designs have the red tubing already permanently fitted to the 

valve. The saddle tapping valve supplied with the RO-Pro System is designed to comply with British plumbing codes.

Fitting The Tank Ball Valve

Remove the plastic cap on the top of the tank. Wrap the thread 3 or 4 times with plumbers tape (Teflon). Connect 
the ball valve to the thread and make sure it is tight but not over-tight. Connect the yellow tubing to the tank ball 
valve. Turn the tank ball valve off.

 Note:

 Do not tamper with the air valve on the low side of the storage tank. It has 

been preset at 8-10 psi by the manufacturers. 

Mounting The Drain Clamp

Position the drain saddle in the desired location (please see notes below), mark spot through thread outlet, remove 
saddle. Drill 1/4” (6.3mm) hole into the drain pipe above the water line of the trap/U-bend. Fix self adhesive foam 
seal over the hole in the drain saddle ensuring that the holes line up. Align the hole drilled in the drain pipe with the 
drain saddle using a drill bit. Make sure to align drain saddle to drilled hole. Attach drain saddle to drain pipe and 
tighten the two screws evenly. Connect the black tubing to the drain clamp. 

Note: 

The drain clamp will fit most standard drain pipe 1 1/2” diameter. It should be installed above the trap/u-bend 

and on the vertical or horizontal tailpiece. If a waste disposal unit is fitted, the drain clamp must not be fitted into the 
same waste pipe. 

Summary of Contents for RO-pro-325

Page 1: ...N INSTRUCTIONS PROSEP FILTER SYSTEMS LTD UNIT G19 RIVER BANK WAY LOWFIELDS BUSINESS PARK ELLAND WEST YORKSHIRE HX5 9DN Tel 01422 377367 Fax 01422 377369 Email domestic prosep co uk Web www prosep co u...

Page 2: ...er System from PROSEP Filter Systems Ltd With proper care your water filtration system will produce high quality drinking water for many years Read carefully and follow the instructions in this manual...

Page 3: ...ical for effective reduction of total dissolved solids System Tested and Certified by NSF International against ANSI NSF Standard 58 for the reduction of Barium Cadmium Copper Cyst Hexavalent Chromium...

Page 4: ...Stage Granular Activated Carbon Post Filter Cartridge Auto shut off valve Operating Pressure 40 120 PSI Operating Temperature 40 110 deg F Recovery Rate 20 25 Product Code Description Service Life PRO...

Page 5: ...you are uncertain run the hot tap for a minute and feel the pipes under the sink to distinguish the cold pipe Do not fit the valve on a bend a join or where there is solder on the copper pipe Attach t...

Page 6: ...ould take 2 3 hours to complete After the second tank is filled you may enjoy the pure water Check for leaks daily for the first week and periodically thereafter You may notice that the water may be m...

Page 7: ...NOTE IF IT IS TOO TIGHT TO OPEN THE HOUSING YOU MAY TRY TO UNPLUG THE FITTING BETWEEN THE RED TUBING AND THE SYSTEMS IN ORDER TO REDUCE THE AIR AND WATER PRESSURE INSIDE THE HOUSING e After opening t...

Page 8: ...ow Normally it takes 2 3 hours to fill the tank Low water pressure and or temperature can reduce production rate Add pressure to storage tank The pressure should be 8 10psi when the tank is empty Slow...

Reviews: